5. Safety information
1. No modifications are allowed to be made to the genera-
tor
2. The speed preset by the manufacturer may not be
changed. The generator or connected devices could be
damaged.
3. Risk of poisoning! Fumes, fuels and lubricants are
toxic. Do not breath in the fumes.
4. Fire risk! Petrol and petrol fumes are highly flammable
and explosive.
5. Motor exhaust gases are toxic. The generator must not
be operated in unventilated rooms. If the generator is to
be operated in well-ventilated rooms, the exhaust gases
must be discharged directly outside via an exhaust gas
hose. Additional requirements for protection against fire
and explosion must also be observed. Even when using
an exhaust hose, toxic gas can still escape. Due to the
risk of fire, the exhaust hose should never be aimed at
combustible material.
6. Never use the generator in rooms with highly flammable
materials.
7. Hot surface! Risk of burning, do not touch the exhaust
system and engine unit.
8. Do not touch any of the mechanically moving or hot parts.
Do not remove any of the protective caps.
9. Protective equipment! Use suitable ear protection
when near the device.
10. Only original parts should be used for maintenance and
accessories.
11. Repair and maintenance work must only be performed by
authorised qualified personnel.
12. Protect yourself from electric shocks.
13. Never touch the generator with wet hands
14. Only use outside with a extension cable which is suitable
for that and is appropriately marked (H07RN).
15. If extension cables or mobile distribution networks are
used, the resistance value must not exceed 1.5 Ω. When
using extension cables, the total length of cables for a
cross section of 1.5 mm2 should not exceed 60 m; for a
cross section of 2.5 mm2, 100 m should not be exceeded.
16. Do not use the generator in the rain or snow.
17. Always turn off the engine when transporting or refuelling.
18. Fuel is combustible and highly flammable. Do fuel the unit
during operation. Do not fuel the unit when someone is
smoking or near open flames. Do not spill any fuel.
19. Do not refuel or empty near naked lights or flames or fly-
ing sparks. Do not smoke!
20. Put the generator on a secure and level place. Turning,
tipping or changing its position during operation is forbid-
den.
21. Install the generator at least 1 m away from the walls or
attached devices.
22. Children must be protected by ensuring that they stay a
safe distance away from the generator.
23. Some parts of the reciprocating internal combustion mo-
tor are hot and may cause burns. The warnings on the
generator must be observed.
24. Emission levels are represented in the technical data un-
der the stated values for sound power level (LWA) and
sound pressure level (LpA) and are not compulsory definite
working levels. Because there is a connection between
emission levels and immission levels, this can not reliably
used to determine the potentially necessary additional
precautions. Influencing factors on the workforce‘s cur-
rent immission level includes the properties of the work
area, other noise sources, air borne sound, etc. such as
e.g. the number of machines and other neighbouring pro-
cesses and intervals, to which the user is exposed. Also
the admissible immission levels can vary from country to
country. However, this information gives the user of the
machine the opportunity to have a better estimation of the
risks and dangers. Occasionally acoustic measurements
should be take after installation in order to determine the
sound pressure level.
25. Warning! Follow the electrical safety regulations that ap-
ply to the location where the generators are used.
26. Warning! Take into account the requirements and pre-
cautionary measures in the event of generators being re-
supplied, depending on the protective measures of this
device and the applicable directives.
27. Generator sets should only be used up to their rated out-
put under the rated ambient conditions. If the application
of the generating set is carried out under conditions which
do not comply with the reference conditions of ISO 8528-
10 (7.1), and if the cooling of the motor or generator is
impaired, e.g. as a result of operating in restricted areas,
a reduction in performance is required.
ATTENTION: Only use unleaded normal petrol as
fuel.
6. Technical data
Generator Inverter
Protection type IP23M
Continuous Power Pnenn (S1) 1000 W
Power Pmax (S2/5min) 1100 W
Power Pmax (S2/5s) 1200 W
Nominal voltage Unenn 230 V∼
Rated current Inenn 4,35 A
Frequency Fnenn 50 Hz
Type drive motor 4 stroke air-cooled
Engine displacement 54 cm³
Max. power (motor) 2.1 kW/2.85 PS
Fuel
Unleaded fuel
This device may not be
operated with E10 petrol
Tank capacity 4.2 l
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Parkside IAN 311314 PGI 1200 A1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info