To do your turning work, position yourself at the machine so
that you can guide the cutting tools effectively on the tool
support.
Only use cutting tools, which are recommended for wood
turning works.
11. Transport
1. Turn the power tool off before it is transported and dis-
connect it from the power supply.
2. Always carry the electric tool with at least one other per-
son. Carry the power tool to the machine bed (12).
3. Protect the power tool against knocks, jolts and strong
vibrations, e. g. when it is transported in motor vehicles.
4. Secure the power tool against tilting and sliding.
5. Never use the protective devices for handling or trans-
port.
12. Cleaning and maintenance
m Warning!
Prior to any adjustment, maintenance or service work discon-
nect the mains power plug!
General maintenance measures
Wipe chips and dust off the machine from time to time using a
cloth. In order to extend the service life of the tool, oil the rotary
parts once monthly. Do not oil the motor.
When cleaning the plastic do not use corrosive product.
Maintenance
There are no parts inside the machine which require additional
maintenance.
Service information
Please note that the following parts of this product are sub-
ject to normal or natural wear and that the following parts are
therefore also required for use as consumables.
Wear parts*: wood turning chisel
* Not necessarily included in the scope of delivery!
13. Storage
Store the device and its accessories in a dark, dry and frost-
proof place that is inaccessible to children. The optimum stor-
age temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust and
moisture.
Store the operating manual with the electrical tool.
14. Electrical connection
The installed electric motor is connected and is ready to work.
The connection complies with the relevant VDE and DIN regula-
tions. The customer-side mains supply and the used extension
line must meet these regulations.
Defective electric connection lines
Often, insulation damages occur on electrical connection lines.
Causes are:
Drag marks if connection lines are led through window or
door clearances.
Kinks due to improper attachment or routing of the connec-
tion line.
Cuts caused by running over the connection line.
Insulation damages caused by pulling the connection line
out of the wall socket.
Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be used and
are hazardous due to the insulation damages.
Regularly check the electrical connection lines for damages.
Please make sure that the connection lines are disconnected
from the mains supply during the check.
Electrical connection lines must comply with the relevant VDE
and DIN regulations. Only use connection lines labelled with
H05VV-F.
The labelling of the connection cable with the type specifica-
tion is required.
AC motor
The mains voltage must be 220 - 240 V~.
Extension cables up to 25 m in length must have a cross-
section of 1.5 mm².
Connections and repairs to the electrical equipment may only
be performed by a qualified electrician.
If you have any queries, please provide the follow-
ing information:
Current type of the engine
Data from the machine type plate
Data from the motor type plate
15. Disposal and recycling
The equipment is supplied in packaging to prevent it from being
damaged in transit.
The raw materials in this packaging can be reused or recycled.
The equipment and its accessories are made of various types
of material, such as metal and plastic.
Defective components must be disposed of as special waste.
Ask your dealer or your local council!
The packaging is wholly composed of
environmentally-friendly materials that can be
disposed of at a local recycling centre.
Contact your local refuse disposal authority for
more details of how to dispose of your worn-out
electrical devices.
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Parkside PDM 600 A1 - IAN 322988 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info