7. Technical data
Mains connection ................................................ 230 V∼ 50 Hz
Motor power ..................................................................1500 W
Operating mode .......................................................................S1
Compressor speed .....................................................2800 min-1
Pressure vessel capacity ..........................................approx. 24 l
Operating pressure ...............................................approx. 8 bar
Theo. intake capacity ....................................approx. 260 l/min
Effective delivery quantity at 7 bar .................approx. 80 l/min
Effective delivery quantity at 4 bar .............. approx. 110 l/min
Effective delivery quantity at 1 bar .............. approx. 150 l/min
Sound pressure level LPA ............................................... 68 dB(A)
Sound power level LWA ..................................................89 dB(A)
Uncertainty KPA/WA ..........................................................2.59 dB
Protection category ...............................................................IP20
Device weight ....................................................... approx. 24 kg
Max. altitude (above mean sea level) ...........................1000 m
The noise emission values have been determined in accordance
with EN ISO 3744:1995.
Wear hearing protection.
Excessive noise can result in a loss of hearing.
8. Before commissioning
Open the packaging and carefully remove the device.
Remove the packaging material, packaging and transport
safety devices (if applicable).
Check that the delivery is complete.
Check the device and accessory parts for transport damage.
If possible, keep the packaging until the end of the warranty
period.
DANGER
The device and the packaging are not children‘s
toys! Do not let children play with plastic bags,
films or small parts! There is a danger of choking
or suffocating!
Before connecting the machine, make certain that the data
on the type plate matches with the mains power data.
Check the device for transport damage. Report any damage
immediately to the transport company which was used to
deliver the compressor.
Install the compressor near the point of consumption.
Avoid long air lines and supply lines (extension cables).
Make sure that the intake air is dry and free of dust.
Do not install the compressor in a damp or wet room.
The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5 °C
to 40 °C). There must be no dust, acids, vapours, explosive
gases or inflammable gases in the room.
The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is
conducted with sprayed water.
The compressor may only be used outdoor briefly when the
ambient conditions are dry.
The compressor must always be kept dry and must not be left
outdoors after work is complete.
9. Attachment and operation
m Attention!
Always make sure the device is fully assembled
before commissioning!
You require the following for assembly:
1x open-ended spanner 14 mm
1x Phillips screwdriver
(not included in the scope of delivery)
9.1 Fitting the wheels (fig. 3)
Fit the supplied wheels (5) as shown.
9.2 Installing the supporting foot (fig. 4)
Fit the supplied supporting foot (7) as shown.
9.3 Installing the air filter (fig. 5, 6)
Remove the transport lid (16) and screw the air filter (4) to
the equipment.
Insert the hose (4d) into the opening of the air filter (4).
9.4 Mains connection
The compressor is equipped with a mains cable with
protective contact plug. This can be connected to any 220 ‒
240 V∼ 50 Hz protective contact socket, with fuse protection
of at least 16A.
Before you use the machine, make sure that the mains voltage
is the same as the operating voltage and the machine power
on the rating plate.
Long supply cables, extensions, cable reels, etc. cause a
drop in voltage and can impede motor start-up.
At low temperatures below +5 °C, sluggishness may make
starting difficult or impossible.
9.5 On/Off switch (fig. 1)
Pull the On/Off switch (3) upwards to switch on the
compressor.
To switch off the compressor, press the On/off switch (3)
down.
9.6 Setting the pressure (fig. 1, 2)
Use the pressure regulator (15) to set the pressure on the
pressure gauge (12).
The pressure set can be drawn from the quick couplings (10,
11).
The vessel pressure can be read off at the pressure gauge (13).
9.7 Setting the pressure switch (fig. 1)
The pressure switch (2) is set at the factory.
Cut-in pressure approx. 5.5 bar
Cut-out pressure approx. 8 bar
9.8 Fitting the compressed air hose (fig. 1, 2)
Connect the plug nipple (14a) of the compressed air hose
(14) to one of the quick couplings (10, 11). Then attach
the compressed air tool to the quick coupling (14b) of the
compressed air hose (14).
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Parkside PSKO 24 A1 - IAN 354867 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info