815525
21
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
21 04/217027-805J
NOTE: There is no gasket on the bottom of glass.
13. Door Gasket Inspection
• Frequency: Prior to heating season
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is o󰀨.
b. To inspect the door rope (gasket), open the door
and see that the door rope extends approximately
1/8 inch (3mm) to 3/16 inch (9.5mm) from the door
rope channel.
c. It should show signs of compaction all the way
around the door where the rope contacts the face
of the appliance. Conrm there are no air leaks.
14. Cleaning Exhaust Blower - Requires No Lubrication
• Frequency: Yearly or as needed
• By: Qualied Service Technician
Task: Contact your local dealer.
15. Cleaning Convection Blower - Requires No
Lubrication
• Frequency: Yearly or as needed
• By: Qualied Service Technician
Task: Contact your local dealer.
16. Preparing Firebox for Non-Burn Season
• Frequency: At the end of the heating season
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is o󰀨.
b. Remove all ash from the rebox and vacuum
thoroughly.
c. Paint all exposed steel, including cast-iron.
- Use the Touch-Up paint supplied with the
appliance; or,
- Purchase paint from your local dealer.
Must use a high-temperature paint made
specically for heating appliances.
17. Remove Ba󰀪e to Access Heat Exchanger Tubes
and Firebox Exhaust Exits
a. Open the right side access door and then open the
glass door.
b. Grasp the bottom of the ba󰀪es and pull up to
dislodge from hook attachment.
c. Use a standard screw driver to unlatch the covers
beneath the ba󰀪es of each side.
d. Re-install in reverse order.
12. Door Latch Inspection
• Frequency: Prior to heating season
• By: Homeowner
The door latch is non-adjustable but the gasket between the
glass and rebox should be inspected periodically to make
sure there is a good seal.
10. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
• Frequency: Yearly or more frequently depending on
ash build-up
• By: Qualied Service Technician/Homeowner
The products of combustion will contain small particles
of y-ash. The y-ash will collect in the exhaust venting
system and restrict the ow of the ue gases. Incomplete
combustion, such as occurs during startup, shutdown, or
incorrect operation of the room appliance will lead to some
soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at
least once every year to determine if cleaning is necessary.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
11. Cleaning the Glass
• Frequency: When clear view of the re pot is obscure
• By: Homeowner
a. Appliance must be completely cool before
cleaning glass.
b. Use a damp paper towel or any non-abrasive glass
cleaner. Wipe o󰀨 with dry towel.
Handle glass assembly with care.
When cleaning glass:
Avoid striking, scratching or slamming glass.
Do NOT clean glass when hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white lm.
Refer to maintenance instructions.
CAUTION
Handle glass with care.
Inspect the gasket to ensure it
is undamaged.
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with
glass assembly removed.
WARNING
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Quadra-Fire Classic Bay 1200 - Pellet - Insert wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Quadra-Fire Classic Bay 1200 - Pellet - Insert

Quadra-Fire Classic Bay 1200 - Pellet - Insert Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info