13-SAFETY DEVICES
Remembering that the draught recommended for the products to work properly is 10 Pa at maximum capacity and 5 Pa at minimum
(according to the technical data sheet found in the user and maintenance manual), adjustments may be required in worse draught
conditions (also due to the position of the ue in areas that are particularly subject to adverse weather such as prevailing winds, snow,
northern exposure, etc.) so as to always guarantee the required negative pressure inside the hopper.
To compensate for the lack of internal negative pressure simply adjust the speed (RPM) of the smoke extractor so as to guarantee the
minimum tabular values.
If the negative internal pressure values are noted to be lower than those indicated, this can also be due to the internal gaskets not being
sealed properly or by the product being worn over time.
OPERATING INSTRUCTIONS ON NEGATIVE PRESSURE INSPECTIONS AND POSSIBLE VARIATIONS OF THE RPM
Connect a pressure gauge to the pressure outlet on the hopper:
In the case of products with a specic pressure outlet in the hopper, access the sampling point and connect the pressure gauge
In the case of products without a dedicated pressure outlet, disconnect the tube of the pressure switch from the pressure outlet on
the hopper, add a “T” on the tube to intercept the circuit, connecting the gauge and reconnect the tube to the pressure outlet on the
hopper.
Possible adjustments of the combustion and consequently of the negative pressure inside the hopper can be implemented in two ways:
A) Change the RPM value of the smoke extractor in the SETTINGS MENU
The available values are from -3 to +3 which, as a percentage, correspond to:
RPM: -10% +10% in Active System products
RPM: -30% +50% in NON Active System products
The percentage variation aects all the power values (1 to 5) proportionally and as a percentage. The percentage variation does not
aect intermediate operating stages such as SWITCH ON, FIRE ON or SWITCH OFF
As the RPM increase, suction also increases and consequently the internal negative pressure, thereby compensating the phenomena
that trigger the alarm.
B) Adjusting the RPM of the gear motor manually in the TECHNICAL PARAMETERS MENU
The pressure switch has a calibration of 10/20 Pa which means that it disarms when the negative pressure inside the hopper drops
below 10 Pa and requires more than 20 Pa negative pressure inside the hopper for it to rearm
The negative pressure value at the minimum power must always be higher than 10 Pa while also maintaining a reasonable margin
that can be used over time due to the gaskets being worn or something similar (at least 12/13 Pa)
The negative pressure at maximum power must always be above 20 so that the pressure switch can rearm when the pressure
switch rearming automated device is activated. The pressure switch rearming procedure (such as after opening the cover to top-up
the hopper), requires the electronics to push the RPM of the smoke extraction fan up to POWER 5 (P5) for a few moments. At P5,
therefore, the negative pressure inside the hopper must always be > 20 Pa (recommended 22/23 Pa to preserve the margin).
N.B. = The TECHNICAL PARAMETERS menus are password-protected to prevent the user from accessing them
inadvertently
Attention! The factory setting on the product is designed to obtain the certied technical data. In the event of data
discrepancy (as for the pellet recipe), the settings may be modied as set out above.
The adjustments must only be carried out by authorised and qualied personnel under their responsibility and by
checking the conformity of the installation beforehand.
Downloaded from www.Manualslib.com manuals search engine
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Red Loto Multiair wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info