602239
9
Zoom out
Zoom in
Vorherige Seite
1/28
Nächste Seite
9
Initial Setup
Output Connections
1. Use RCA cables to connect the output jacks of the 3Sixty.3 to the input jacks on the amplifier(s) you have selected for your system. The 3Sixty.3 will
allow you to connect up to 8 channels of output. Follow the instructions in your amplifier manual for connecting the rest of your system.
NOTE: DO NOT chassis ground any of the leads as unstable operation may result & ensure to follow the diagram for proper signal polarity.
2. Based on the input circuit of your amplifier, select either a balanced or unbalanced output for the 3Sixty.3 to match your amplifiers input. The 3Sixty.3
utilizes a special compensation network to ensure in either position the maximum output voltage is 8VRMS. For most RF amplifiers you are going to want
the switch positioned in the unbalanced position.
PC Software Installation
1. Insert the supplied 3Sixty.3 setup disk and follow the on screen prompts to load the software. If a prompt does not appear you will have to select the CD
ROM drive on you PC to open the 3Sixty.3 setup disk, and select the file “RF3SixtyUI.msi” and follow the on screen prompts.
NOTE: A PC is required for initial setup and adjustments for the 3Sixty.3 unit to properly work with your system. The PC must use a Windows XP, VISTA,
or 7 OS with at least one USB connection and have an internet connection.
2. The 3Sixty.3 user interface (UI) will place the RF icon on your desktop. Double click the RF icon to open the UI. In the lower right corner you will see a
prompt to update the UI if an update is available (must have a working Internet connection). If the UI is up to date you will have a green check mark in the
lower right corner and it will say “You already have the latest version” if you move your curser over it. If an update is available double clicking on it then
follow the on screen prompts to update your UI. Close the UI.
NOTE: You can also manually check for updates by moving the curser over the RF logo in the upper left hand corner and select “Check for updates” This
will ensure you have the latest UI version and 3Sixty.3 processor firmware version.
3. To check which version of UI and processor firmware you are using moving the curser over the RF logo in the upper left hand corner and select “About”.
NOTE: In order to check the version number of the 3Sixty.3 processors firmware the 3Sixty.3 processor must be connected to the PC through the USB
cable.
Connecting to a PC & Updating
NOTE: Before starting the system ensure that the volume is all the way down on the source unit, the factory or any external EQ’s are set to flat, the
amplifier(s) EQ is set to flat and the amplifier(s) gain(s) are set to minimum.
1. Connect the unit to a PC; turn the unit on by turning the key to the accessory position (3Sixty.3 LED should be white), using the supplied USB cable,
connect the 3Sixty.3 processor to the PC (3Sixty.3 LED should turn solid blue). Open the UI. To disconnect the unit, close the UI, Disconnect the USB cable
(3Sixty.3 LED should turn white), and turn off the 3Sixty.3.
NOTE: The unit must be powered on (LED should be white) before connecting to a PC or the unit will enter DEMO mode. DEMO mode allows you only
limited function of the user interface. In DEMO mode you can update your processor but you cannot read or write EQ functions.
NOTE: The remote level control is disabled and will have no LED on while connected to the PC. The remote simulator at the top of the user interface (UI)
screen is used to preform the wired remote controllers functions while connected to a PC.
2. Update the unit; Open up the UI by double clicking the RF icon on your desk top. In the lower left corner of the UI there should be a green circle and it
should display “device connected”. The LED should switch from white to blue (flashes blue when communicating). If the 3Sixty.3 processor is up to date
you will have a green check mark in the lower right corner and it will say “You already have the latest version” if you move your curser over it. If an update
is available double clicking on it then follow the on screen prompts to update your 3Sixty.3 processor.
NOTE: If the device is plugged in and the UI is still displaying “No device connected’ check that the unit is powered on, and the cable connections are
good.
NOTE: You can also manually update the 3Sixty.3 processor firmware updates by selecting the “DEVICE” tab in the upper left hand corner, then selecting
“Upgrade Firmware” from the drop down menu. Follow the on screen prompts to update your 3Sixty.3 processor.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Rockford Fosgate 3 SIXTY.3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Rockford Fosgate 3 SIXTY.3

Rockford Fosgate 3 SIXTY.3 Bedienungsanleitung - Deutsch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info