DISMANTLING
If one of the motors cannot be made
to operate correctly, use of that motor
can be “disabled” by setting the
corresponding switch on the board
(SW1: switches 1 and 2 for motors 1
and 2).
The motor thus “disabled” can be
removed. The unit operates on
the other motor.
16
WORK THAT MAY BE REQUIRED
15
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
Before carrying out any other types of work, disconnect
the Sanicubic Classic from the power supply.
UK
INSTRUCTIONS ONLY FOR QUALIFIED
PROFESSIONAL SPECIALISTS
A
LARM ON APPLIANCE
REMOVING A MOTOR
D
ISCONNECT THE UNIT FROM THE POWER
S
UPPLY (the yellow indicator light must be flashing off).
INSTRUCTIONS RESERVED EXCLUSIVELY
FOR QUALIFIED PROFESSIONAL SPECIALISTS
F
1
16
5
16
Unclip the cover.
Unscrew the collar on the
faulty motor (the check valve
stays in place while the motor
is being repaired).
A
Unscrew the collar .
Remove the motor power
wires from the screw
connector.
C
B
Remove the screws from
the inspection cover.
Use the handle to lift the
motor carefully.
E
D
Please contact the service
engineer. You can operate the
lifting station in minimum confi-
guration with just one motor.
Remove the screws of
the faulty motor from the
inspection cover.
F
Put the inspection cover back
in place.
Reconnect the discharge pipe.
Use the plug to close off
the motor cable outlet in the
inspection cover. Fix using
the hose clip .
B
G
Operations on the electronic
board (cf. illustration
):
set the switch corresponding
to the number of the faulty
motor from ONto OFF:
1 = motor 1
2 = motor 2
In this configuration, the unit
will not switch to “alarm”
status and the electronic
board only powers the motor
remaining in place.
PUTTINGTHEMOTOR
BACK INPLACE
Remove the plug and the
inspection cover.
Screw the motor onto the
inspection cover and put the
cover back in place.
Reconnect the motor power
wires (cf. illustration ).
Warning:
Comply carefully with the
colour code:
Blue wire with the blue wire
Brown wire with the brown
wire
Green wire with the green
wire
White wire with the white
wire
Set the motor switch on the
board to ON.
Reconnect the discharge
pipe.
Connect the unit to the
power supply.
Carry out a complete test
for commissioning (cf.
paragraph ).
11
3
16
G
1
1
6
The unit beeps to show that it
is no longer under power.
Firstinterventionsontheappliance
(*) Warning: if pumping height is high, 90° elbows should be avoided.
MO: Manual Over ride
INDICE
01.12
A
B
C
D
E
G
2
16
3
16
4
16
6
1
6
PROBABLE CAUSES
faulty electronic board
Outlet pipe blocked
Discharge head too high
Faulty detection system
•faulty electronic board
Check valves either leak or
are broken
ACTION TO BE TAKEN
Consult the SFA customer
services
Unblock the outlet pipe
Check the installation (*)
Consult the SFA customer
services
Clean or change check valves
Second interventions on the appliance
FAULT
1 Alarm + general alarm LED
flashing
2 Alarm + general alarm LED
lit
3 general alarm LED
4 Alarm + general alarm LED
+ yellow mains LED flashing
PROBABLE CAUSES
Faulty detection system
Blocked pipe
Pump blocked or seized
The appliance has the follo-
wing problem: blocked pipe,
seized or blocked pump(s)
The appliance has been
affected by a mains power cut
Mains power cut
ACTION TO BE TAKEN
Consult the SFA customer
services
Make the pumps work (MO
button) in several bursts.
Consult an SFA approved
engineer
Press on one of the two MO
buttons to reset (alarm stops)
To stop the alarm, press on
one of the two MO buttons
Check the electrical system
Consult the SFA customer
services
FAULT
The motor does not start but
the MF works
Pumps on constantly
Pumps work intermittently
N°163 PRO SANICUBIC 2 Classic
N163 R4LC Feuillet SPECIAL PRO Sanicubic 2 Classic:5622 NOTICE N°129 EXE 30/01/12 17:44 Page 2
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur SANICUBIC 2 Classic Expert-line wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info