ALARM OPERATION
1/ General alarms:
High level alarm:
If the water level in the unit is abnormally high: the buzzer is
triggered and the red LED comes on; the other motor starts up
3 seconds later (see the illustration showing the control
keyboard).
Temporary alarm:
If one of the 2 motors runs for more than 1 minute: the buzzer is
triggered and the red alarm LED comes on; the other motor starts
up 3 seconds later.
2/ Resetting the general alarms:
If the problem that has triggered one of the alarms referred to
above ceases, the buzzer stops, but the red alarm LED stays
on to memorize the fact that the system has met with a
problem.
The “Reset alarm” key on the keyboard is used to switch the
buzzer off in all cases, but it only switches the red LED off if
the problem that triggered the alarm has been dealt with. This
avoids the risk of having a system “abandoned” in fault status.
UNIT ALARM
9
DRAINING
The SANICUBIC
®
Classicunit is fitted with 2 plugs ( ).
Disconnect the unit from the power supply.
To drain the unit
1- Unclip the cover.
2- Remove one of the 2 plugs.
3- Insert a wet utility vacuum cleaner pipe to drain the unit. The
port diameter is 40 mm.
4- When the unit has been drained, put
the plug and then the cover back in place.
FIXING THE SANICUBIC UNIT TO THE FLOOR
The SANICUBIC
®
Classicunit is equipped with fittings to hold it
on the floor and
prevent it from turning or moving.
1- Place the unit on the desired spot.
2- Draw the outline of the unit.
3- Position the brackets and fix them to the floor as shown on the
template diagram ( ).
4- Put the unit back in place.
5- Fix the unit in place with the screws.
ELECTRICAL CONNECTIONS
1- The electrical installation work must be carried out by a
qualified electrician.
The electrical installation must comply with the standards in
force in the country concerned
2- The power supply must be of the class 1 type. The unit must be
connected via an earthed connection box. The electric power
circuit must be protected by a high-sensitivity 30 mA differential
circuit breaker set at 20 A. The connection must be used solely
to power the
SANICUBIC
®
Classic
. If the power lead on the unit
is damaged, it must be replaced by the manufacturer or its
after-sales service to avoid all danger.
1
8g
8g
1
8h
8h
8i
motor 1
LED
motor 2
LED
“Alarm”
LED
“Mains”
LED
motor 1
“Override”
motor 2
“Override”
“RESET”
Alarm
CONFORMITY WITH STANDARDS
SANICUBIC
®
Classiccomplies with standard EN 12050-1 (lift
station for household waste containing faeces) and with the
European directives covering construction products, electrical
safety and electromagnetic compatibility
This unit must be installed and used in compliance with
European installation standard EN12056 and with local
requirements.
10
COMMISSIONING
1- Once the plumbing and electrical connections have been
made, check that the connections are watertight by
letting water flow successively through each inlet used.
Make sure that the unit is operating correctly by carrying
out at least two start cycles with water to test the system.
2 -
WARNING! Do not operate the motors in override
status (by pressing the pushbuttons
on the control box) until the pumps have been filled
with water. Operation without water damages the
maceration system.
11
USE
1- The SANICUBIC
®
Classic unit is designed to drain off
household waste water. Any other use will invalidate the
guarantee. Do not dispose of sanitary towels, condoms,
hygiene articles, oils, solvents, acids, or any other poten-
tially corrosive or explosive liquids etc., via the unit.
2-
WARNING: In the event of a power failure, stop
draining any water from the equipment connected
to the SANICUBIC
®
Classic unit.
3- Do not install or use the unit in a zone where there is a
risk of explosion.
12
GUARANTEE
The SANICUBIC
®
Classic unit is guaranteed for two years
(parts and labour) provided that it has been installed and
used in compliance with the present instructions.
14
MAINTENANCE
A visual check of the lift station must be made once a month
to make sure it is operating correctly, and the installation
must be inspected regularly (once a year) by a qualified
person. Meanwhile if encounter technical problems, please
ask our after-sales service for advice. If the power supply
cable of the unit is damaged, it must be replaced by the
manufacturer or its after-sales service to avoid all danger.
13
9257 N150 SANICUBIC NOTICE:5622 NOTICE N°129 EXE 19/11/10 13:36 Page 7
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur SANICUBIC 2 Classic Expert-line wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info