699075
77
Zoom out
Zoom in
Vorherige Seite
1/114
Nächste Seite
SATEL INTEGRA 75
6.5 Times
Global entry delay parameter taken into account in the delayed zones, for which the
programmed ENTRY DELAY is equal to 0.
Global alarm time time of signaling alarm in keypads, proximity card arm/disarm devices,
proximity card readers and DALLAS chip readers.
No armed indication after time counted from the moment of partition arming, during which
information about armed status is displayed on the keypads. Programming the value 0
means that keypads will indicate the armed status as long as the partition is armed.
AC loss report delay time during which the control panel must not receive AC power so
that information of it can be saved to the event log. Having programmed the value 0
means that the information of AC power loss will not be saved to the event log.
Tel. line loss report delay time during which abnormal voltage must be on the telephone
line for the control panel to report the telephone line trouble. A delay in reporting the
trouble prevents sending information about short-time voltage dips (e.g. during a phone
call) or decays.
Default part. block time the time period during which the WITH TEMPORARY BLOCK type
partitions with enabled DEFAULT BLOCK TIME option will be blocked.
Summer/winter time [Daylight saving] the control panel can automatically adjust the clock
settings due to a change from the summer time to the winter time according to the
selected schedule.
Summer time fromif the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the summer
time (moved forward).
Winter time from if the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the winter
time (moved back).
RTC clock correction [Clock adjustm.] if the accuracy of control panel clock is inadequate,
the clock settings may be adjusted once per 24 hours (at midnight) by a defined time. The
correction time is programmed in seconds. The maximum correction can be ±19 seconds
per 24 hours.
Time server if the control panel is to synchronize the time with the server (automatically
and after suitable function is enabled by the installer or master user), enter the address of
time server supporting the NTP protocol. Time synchronization is possible for the
INTEGRA 128-WRL control panel and any other panel to which the ETHM-1 / ETHM-1
Plus / INT-GSM module is connected.
Time zone if the control panel is to synchronize the time with the server, indicate the time
zone, i.e. the difference between the universal time (GMT) and the zone time.
Do not report time server connection trouble [No t.serv.trbl] with this option enabled, no
trouble will be reported if there is no communication with the time server.
6.6 Service options and parameters
In the keypad, most of the options and parameters, as described below, are available in SM
SETTINGS
submenu.
Service access code a code that allows access to the service mode, as well as some
functions in the user menu.
Disable service mode [Block SM] with this option enabled, entering the service mode
from pins (by hardware means) will be impossible (entering the service mode from pins
will only be possible if the control panel factory settings are restored).
77

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel Integra 64 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel Integra 64

Satel Integra 64 Zusatzinformation - Deutsch - 121 seiten

Satel Integra 64 Bedienungsanleitung - Deutsch - 54 seiten

Satel Integra 64 Installationsanweisung - Deutsch - 38 seiten

Satel Integra 64 Kurzanleitung - Deutsch - 2 seiten

Satel Integra 64 Bedienungsanleitung - Englisch - 51 seiten

Satel Integra 64 Installationsanweisung - Englisch - 36 seiten

Satel Integra 64 Bedienungsanleitung - Holländisch - 52 seiten

Satel Integra 64 Kurzanleitung - Holländisch - 24 seiten

Satel Integra 64 Zusatzinformation - Holländisch - 121 seiten

Satel Integra 64 Installationsanweisung - Holländisch - 35 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info