782280
22
Zoom out
Zoom in
Vorherige Seite
1/72
Nächste Seite
22 GB
Only a qualied electrician is permitted to connect the
machine and complete repairs on its electrical equip-
ment.
In the event of enquiries please specify the following
data:
Motor manufacturer
Type of current of the motor
Data recorded on the machine’s rating plate
Data recorded on the switch’s rating plate
13. Maintenance
If specialist personnel must be brought in for extraor-
dinary service or repairs during the warranty period
and thereafter, please contact a service provider rec-
ommended by us or contact the manufacturer directly.
Overhauls, maintenance work, cleaning, as well as
the elimination of any malfunctions must only be un-
dertaken after turning off the motor.
All protective and safety equipment must be rein-
stalled immediately upon completion of any repair or
maintenance work.
Regular maintenance
The regular maintenance decribed above and in the
paragraph below can be carried out by unskilled per-
sonnel.
Do not oil the plunge cut saw, cause cutting must be
carried out in dry conditions; all rotating parts are self-
lubricating.
During maintenance, wear protective gear if possible
(accident-prevention goggles and gloves).
Remove cuttings when necessary both from the cut-
ting area, work surfaces and support bases.
Use of an aspirator or brush is recommended.
ATTENTION: Do not use compressed air jets!
Regularly check blade conditions: if difculties should
arise during cutting, have it sharpened by skilled per-
sonnel or replace it if necessary.
Assistence
When in need of skilled personnel for special main-
tenance, or for repairs, both during and following the
guarantee period, always apply to authorized centres
for assistance or directly to the manufacturer if there
is no authorized centre in your area.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consumable.
Wear parts*: Carbon brushes, saw blade
* Not necessarily included in the scope of delivery!
Cutting with rails
1. Place the machine in the guide rails. can be read-
justed using the hex driver included in the deliv-
ery, when there is the risk of the adjusting screws
releasing by themselves.
2. Turn on the machine by pressing the on/off switch
(4).
3. Press the dip trigger (3).
4. Press the saw downwards to reach the sawing
depth. During rst use the rubber lip is sawn off
and thus splitter protection is guaranteed up to
the saw blade.
5. Push the saw uniformly forwards.
6. Turn off the machine and tilt the saw blade to the
top when the saw cutting is complete.
Sawing with dust suction
Connect the suction hose to the exhaust nozzle - Ø
38 mm (12).
12. Electrical connection
The installed electric motor is completely wired
ready for operation.
The customer’s connection to the power supply
system, and any extension cables that may be
used, must conform with local regulations.
Important remark:
The motor is automatically switched off in the event
of an overload. The motor can be switched on again
after a cool ing down period that can vary.
Defective electrical connection cables
Electrical connection cables often suffer insulation
dam age. Possible causes are:
Pinch points when connection cables are run
through window or door gaps.
Kinks resulting from incorrect attachment or laying
of the connection cable.
Cuts resulting from running over the connecting ca-
ble.
Insulation damage resulting from forcefully pulling
out of the wall socket.
Cracks through aging of insulation.
Such defective electrical connection cables must not
be used as the insulation damage makes them ex-
tremely hazardous.
Check electrical connection cables regularly for dam-
age. Make sure the cable is disconnected from the
mains when checking.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F.
The printing of the type designation on the connec-
tion cable is mandatory.
Single-phase motor
The mains voltage must coincide with the voltage
specied on the motor’s rating plate.
Extension cables up to a length of 25 m must have
a cross-section of 1.5 mm2.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach KS55PS Kity wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info