Installation instructions
Dear Customer,
Congratulations on pur-
chasing this STEINEL Inf-
rared Sensor and thank
you for the confi dence
you have shown in us.
You have chosen a high-
quality product that has
been manufactured,
tested and packed with
the greatest care.
Please familiarise yourself
with these instructions
before attempting to in-
stall the sensor since
prolonged reliable and
trouble-free operation will
only be ensured if it is
installed properly.
We hope your new Infra-
red Sensor will give you
lasting satisfaction.
W
Disconnect the power
before attempting any
work on the motion
detector.
W
The electrical connec-
tion lead must be dead
during installation.
Therefore, switch off
the power fi rst and
use a voltage tester to
check that the power
supply is disconnected.
W
Installation of the
sensor involves work
on the mains power
supply. This work must
therefore be carried
out professionally in
accordance with the
applicable wiring regu-
lations and electrical
operating conditions.
(
D - VDE 0100,
A - ÖVE-EN 1,
- SEV 1000).
W
Please note that the
sensor must be pro-
tected by a 10 A circuit
breaker. The mains
supply lead must be
no greater than 10 mm
in diam-eter.
Safety warnings
12
Principle
The integrated pyroelec-
tric infrared detector
senses the invisible heat
radiated from moving
objects (people, animals,
etc.). The heat detected is
electronically converted
into a signal that switches
on loads (e.g. a light) con-
nected to it. Heat is not
detected through obsta-
cles, such as walls or
panes of glass. Heat ra-
diation of this type will,
therefore, not trigger the
sensor.
With a detection angle of
160° and a max. reach of
12 m the sensor watches
over an area of approx.
165 m
2
. If you only wish
to cover a smaller area,
reach may be reduced
by tilting the sensor unit.
Using the swivel mount
supplied, the sensor
unit can also be turned
horizontally, making it
possible to target the
detection zone exactly
as you choose. The
detection angle can also
be adjusted to suit individual
requirements by fi tting
shrouds.
Important: the safest mo-
tion detection is obtained
when the device is moun-
ted and aligned laterally to
the walking direction and
no obstacles (such as
trees and walls, for ex-
ample) obstruct the view.
(s. fi g. page 2)
Installation
(s. fi g. page 3)
The site of installation
should be at least 50 cm
from a light because heat
radiated from it may trig-
ger the sensor uninten-
tionally. To obtain the spe-
cifi ed reach of 12 m, the
sensor should be installed
at a height of approx. 2 m.
Please ob-serve the safe-
ty warnings on page 12.
Installation procedure:
1. Undo screws on hous-
ing 1 2. Do not detach
wir-ing from terminal
block, but gently pull
entire terminal assembly,
including sensor unit 2
(cylindrical section), to
remove it.
3. Hold mounting plate 3
against wall/ceiling, mark
drill holes, paying atten-
tion to wiring runs con-
cealed in wall/ceiling. Drill
holes, insert wall plugs
(6 mm). 4. Break open
pre-punched cable entry
holes as appropriate for
concealed 4 or surface-
mounted 5 installation,
insert grommets, pierce
and pass cable through.
Note: For surface-mount-
ed wiring, it is recommen-
ded to install the swivel
mount 6 (see below).
Alternatively, the unit may
be pierced at the thinner
section to pass the cable
through. 5. Screw mount-
ing plate 3 to wall.
6a) Connecting the
mains lead
The mains lead consists of
a 2-3 phase cable
L = phase conductor
N = neutral conductor
PE = protective-earth
conductor
If you are in any doubt,
you must identify the
cables using a voltage te-
ster; then disconnect the
power supply again.
The phase (L) and neutral
conductor (N) are connec-
ted according to terminal
assignment. The protecti-
ve-earth conduct-or is
connected to the earth
terminal .
A mains switch for ‘ON’
and ‘OFF’ switching can
of course be installed in
the mains lead.
6b) Connecting the load
supply lead
The load supply lead (e.g.
light) is also a 2 to 3-core
cable which is connected
to terminals N and L. The
live conductor must be
connected to the terminal
marked L.
Connect the neutral con-
ductor to the terminal
marked N together with
the neutral conductor of
the mains power supply
lead. The protective-earth
conductor is connected to
the earth terminal .
7. Once wiring is complet-
ed, insert terminal block
together with sensor unit
2 into mounting plate 3,
t housing cover 1 and
secure in place with faste-
ning screws.
13
The swivel mount 6 allows
you to turn the motion
detector horizontally. This
provides additional adju-
stment for the detection
zone.
1. Press cupped pieces
7 out of swivel mount 6
provided with sensor unit.
2. Hold swivel mount 6
against wall and mark drill
holes, drill the holes, insert
wall plugs, pass cable
through. Connect as de-
scribed in „Installation“.
3. Pass screws through
Installation with swivel mount
cupped pieces 7 and
secure swivel mount 6 in
such a way that the screw
head is positioned on the
smooth side and the
domed side rests against
the mounting plate 3 (see
diagram).
GB
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel IS 2160 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info