has inexplicable behavior or the display shows
characters without any logic).
6.6 Control panel alarm causes and resetting
During generating set use, alarm signals may be
displayed referring to engine oil checks. After
checking the engine oil, the control panel must
be reset in the following way:
Alarm: the red ‘service’ light is flashing.
Cause: 50 hours have elapsed since the latest
engine oil change and oil level should be
checked.
How to reset the alarm: with panel turned off,
press the partial counter key (Fig.30 Ref.9) and
while holding it down, turn the panel on and re-
lease the push-button when the unit has started
up
Alarm: the red ‘service’ light is lit.
Cause: 100 hours have elapsed since the latest
engine oil change and engine oil should be
changed.
How to reset the alarm: turn on the panel and
wait for the generating set to start. Now press the
button hidden under the small hole in the bottom
left corner (Fig.30 Ref.10) and release it immedi-
ately thereafter. Wait a couple of minutes before
turning the generating set off.
Alarm: the display unit shows random charac-
ters.
Cause: malfunctioning due to low voltage during
start-up (low battery, cable cross-section too
small). In this case, just turn Off and On the con-
trol panel.
In certain situations, data of internal microproc-
essor of the panel may be subject to permanent
alterations and prevent running of generating set.
In this case, to restore the functionality of panel is
necessary to completely re-initialize (contact the
Service).
6.7 Automatic Version (optional)
If you wish the start-up batteries to be recharged
automatically in the En 2510 B generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig.32) instead of the manual con-
trol panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
9 Hour or voltmetric changeover switch button
10 Reset
11 Battery charged indicator
12 Automatic function indicator
13 AUTO/MAN switch for the automatic or man-
ual function
6.8 MANUAL operation
See section 6.1
6.9 AUTOMATIC operation
Turn the AUTO/MAN switch (Fig.32 Ref.13) to
the AUTO position and set the start-up switch
(Fig. 32 Ref. 1) to ON position.
The automatic function indicator (Fig.32 Ref.12)
will light up.
When the voltage at the ends of the 12V DC ter-
minals of the generating set is lower than 11.5
Volts, the generating set will begin the start-up
procedure (similar to that of the manual opera-
tion).
During the operation in automatic mode, the dis-
play (Fig.32 Ref.2) will show the total running
hours of the generating set. Press the hour or
voltmetric changeover switch button (Fig.32
Ref.9) to display the voltage at the ends of the
12V DC terminals, i.e. at the ends of the battery.
When the battery is charged, and anyway after at
least 15 minutes’ running, the battery charged
hours indicator (Fig.32 Ref.11) will light up and
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Telair Energy 2510b wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info