Presence simulation (AWS)
The assigned channels are switched. Operation is now possible again.
During operation, the current brightness values of the channels are
checked and where applicable saved with the time information.
The values thus collated are saved in the device every 24 hours.
After 7 days, the old values are overwritten and resaved.
After start-up, no further values are saved; a presence simulation
sequence cannot be started until a week has lapsed.
After a RESET and/or power is restored, the presence simulation values are
maintained in the device .
12.0 Function in timer module LUXOR 414
Info:
The dimmer module LUXOR 405 can be taught-into all 8 channels of the
timer module (see Operating Manual LUXOR 414, Section 13).
Behaviour with switching time/astronomical time
The percentage value set in the timer module UXOR 414 is output.
Behaviour with switching time/astronomical time
If the sensor is taught into a channel in addition to the timer, the night-
time interruption (i.e. the idle period) acts on the dimming function rather
than on the astronomical time. Astronomical times are always used.
Central functions
- Panic function
If this function is active during a timer command, the timer command
is not used until the function is terminated.
- Presence simulation (AWS)
If this function is active during a timer command, the does not react to the
AWS taught-in channel.
Astronomical time/nighttime interruption (idle period) (see Table)
Switching time
With normal switching times, the nighttime interruption (idle time)
has no function. The switching time is always used.
Astro -
evenings
Sunset
Nighttime
interruption
Start
Nighttime
interruption
End
Astro mor-
nings
Sun
rise
Explanation
Times
Switching
16:10
ON
20:00
OFF
6:00
ON
8:10
OFF
Winter
Normal
sequence
Times
Switching
21:30
20:00
OFF
6:00
4:50
OFF
Summer
remains OFF
Times
Switching
19:30
ON
20:00
OFF
6:00
5:55
OFF
evenings only
ON
Times
Switching
20:30
20:00
OFF
6:00
ON
6:55
OFF
mornings only
ON
13.0 Function in combination with sensor modu-
Info:
The dimmer module LUXOR 405 can be taught-into the dimming channel
on the sensor module LUXOR 411 module (see Operating Manual
LUXOR 411_412 Section 10).
The dimmer module LUXOR 405 reacts only to twilight (80 secs. delay).
When the set Twilight function is underrun, the channels assigned to the
Twilight function are switched to 100 % (for programmes P1, P2 and P4,
but not P3).
When the set Twilight function is exceeded, the channels assigned to the
Twilight function are switched to 0 % (for programmes P1, P2 and P4, but
not P3).
In programme P3, the dimmer module does not react to the sensor module.
If the panic function, a motion sensor, a light setting or presence
simulation are active, the dimming module will not react to the sensor
module.
Relationship between twilight, idle time and output status
(see Table)
Twilight
Idle period
% value
(LUXOR 414)
Sensor
Channel
(LUXOR 405)
getting dark 0 % was present is disabled unchanged
getting dark >0 % was present is enabled 100 %
it is dark 0 % approaching being disabled 0 %
it is dark >0 % approaching being enabled 100 %
getting bright 0 % was present remains disabled unchanged
getting bright >0 % was present remains enabled 0 %
it is bright 0 % approaching being disabled unchanged
it is bright >0 % approaching being enabled unchanged
14.0 Technical data
Operating voltage: 230 V~, +10 % to -15 %
Mains frequency: 50 Hz
Power consumption: 3 VA
Key / switch connecting cable: 230 V phase-independent
Key / switch cable length: up to 100 m (NYM, H05/H07, NYIF)
Dimmer load cable length: up to 100 m
2-wire connection for COM: Any cross-section / max. length 100 m
Permitted ambient temperature: –10 °C ... +50 °C
Protection class: II subject to correct installation
Degree of protection: IP 20 in accordance with EN 60529
Dimmer outputs: per channel 20 ... 300 VA
for one channel: 20 ... 500 VA
Load type: Automatic detection of R, C and L load
Short circuit: the outputs are short-circuit proof (indicator )
Overtemperature: monitored with cut-out (indicator )
automatic detection of R, C loads (reverse phase control) and L load
(reverse phase control)
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Theben Luxor 405 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Theben Luxor 405

Theben Luxor 405 Bedienungsanleitung - Deutsch - 5 seiten

Theben Luxor 405 Bedienungsanleitung - Holländisch - 5 seiten

Theben Luxor 405 Bedienungsanleitung - Französisch - 5 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info