Torqeedo batteries are specially designed for installation and use in marine appli-
cations.
Keep the following points in mind when planning:
Batteries must be able to be xed mechanically.
It must be possible to install the ventilation adapter in closed storage
rooms or cabins (Power 48-5000 only).
Select a location that corresponds to the IP protection class of the battery;
information on this can be found in the respective operating manual.
Make sure that the intended installation location offers sufcient space for
the wiring.
Charger units
NOTE! To charge the batteries in the boat, a land connection in the boat with
galvanic isolator is required according to applicable national requirements (e.g.
DIN EN ISO 13297, ABYC E-11).
Keep the following points in mind when planning:
Torqeedo recommends using one charger unit per battery.
Choose a place in the boat where there is no stagnant air to ensure cooling
of the charger unit.
Select a location that corresponds to the IP protection class of the charger
unit; information on this can be found in the respective charger unit operat-
ing manual.
Make sure that the intended installation location offers sufcient space for
the wiring.
Accelerator lever
If you use a Cruise R, you need an accelerator lever to control the motor.
Keep the following points in mind when planning:
The accelerator lever must be easily accessible and operable from the
control position.
The display must be easy to read from the control position.
The accelerator lever must have enough space to be operated without
restriction.
Emergency kill switch, kill switch, drive enable, on/off switch
Depending on the conguration of your Torqeedo system, you can install differ-
ent components.
Keep the following points in mind when planning:
Kill switches must be installed near the steering position, this is the only
way the driver can be connected to the kill switch with the rip cord.
Emergency kill switches must be installed in such a way that they are easily
accessible at all times.
Plan the installation location of the emergency kill switch so that it cannot
be triggered accidentally (e.g.in downward gradients)
Plan the installation location of the on/off switch so that there is no danger
of injury (e.g. by getting caught on the key switch)
Plan the installation location of the switches so that they cannot be acci-
dently actuated.
6.2.2 External loads
Torqeedo recommends that loads that do not affect the Torqeedo system, such as
radios, lighting, etc., should be operated via a separate onboard power supply.
When using external batteries, the energy consumption of auxiliary loads s not
taken into account when calculating the range.
When using auxiliary loads, the additional power consumption must be taken
into account and the battery bank must be designed according to the total power
consumption.
6.2.3 Wiring
The wiring of your Torqeedo system depends on the components installed. You
can nd the connection diagram for your system in the Service Center section of
our website: www.torqeedo.com
Keep the following points in mind when planning:
An earthing point is required for your Torqeedo system. Take into account
the connection and the cables required for this in your planning. The
required cable cross-sections can be found in the section Tools, equipment
and material.
61

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Torqeedo Cruise 3.0 FP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Torqeedo Cruise 3.0 FP

Torqeedo Cruise 3.0 FP Bedienungsanleitung - Holländisch, Dänisch - 92 seiten

Torqeedo Cruise 3.0 FP Bedienungsanleitung - Französisch, Italienisch - 92 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info