689434
13
Zoom out
Zoom in
Vorherige Seite
1/19
Nächste Seite
EN 13
local air conditioner PAC 3550 PRO
Automatic defrost
At low ambient temperatures, ice may form at the evaporator.
The device will then carry out an automatic defrost.
The compressor switches off and the fan keeps running until
defrosting is completed. The duration of the defrost process can
vary.
Do not switch off the device during automatic defrost. Do not
remove the mains plug from the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Observe the operating temperature according to the
Technical data chapter.
Check the filling level of the condensation tank, and empty
it if necessary. The FLindication (condensation tank full)
must not light up.
Wait for 10minutes before restarting the device.
If the device is not starting, have the electrics checked by
a specialist company or by Trotec.
The device works with reduced or no cooling capacity:
Check whether cooling mode is selected.
Check the proper fit of the exhaust air hose. In case of
kinks, bends or blockage in the hose, exhaust air cannot
be discharged. Clear the way for the exhaust air.
Check the position of the ventilation flaps. They should be
opened to the maximum.
Check the proper fit of the supply air hose. In case of
kinks, bends or blockage in the hose, supply air cannot be
fed. Clear the way for the supply air.
Check the air filter(s) for dirt. If necessary, clean or replace
the air filter(s).
Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre
if required.
Check whether any windows and/or doors of the room are
open. If so, close them. One window has to remain open
for the exhaust air hose nonetheless.
Check the temperature setting at the device. Reduce the
set temperature if it is higher than the room temperature.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
Check whether the ambient temperature equals the target
temperature (in cooling mode). The compressor will not
switch on unless the respective temperature is reached.
The compressor may start up with a delay of 3min, as it is
provided with an internal protection against direct restart.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
The device does not respond to the infrared remote control:
Check whether the distance between remote control and
device is too large and reduce it if necessary.
Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
Check the charging status of the batteries and change
them if required.
If the batteries have only just been changed, check them
for correct polarity and change them if required.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec PAC3550PRO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec PAC3550PRO

Trotec PAC3550PRO Bedienungsanleitung - Deutsch - 20 seiten

Trotec PAC3550PRO Bedienungsanleitung - Holländisch - 22 seiten

Trotec PAC3550PRO Bedienungsanleitung - Französisch - 22 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info