484616
15
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
15
Fault Cause Rectification
No LED is shining, the device is
switched on and is supplied with
operating current.
Automatic restart is blocked,
e.g. after a power failure.
Reset (fault reset) by switching off, waiting 5 seconds and
then switching on again.
After switching on (winter and sum-
mer operation) none of the LEDs
are lit.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V battery voltage, charge if necessary.
Check all electrical plug connections.
Check the unit or vehicle fuse and replace if necessary
(see fuses).
The green LED comes on when the
unit is switched on but the heater
does not operate.
The temperature setting on the
control panel is lower than the
room temperature.
Select higher room temperature at the control panel.
After switching on the heating system,
the green LED shines and
the red LED flashes with 5 Hz,
the red LED flashes with 1 Hz,
the red and the yellow LEDs flash
alternately with 1 Hz.
Open window above cowl
(window switch).
Under-voltage.
Battery voltage is too low
< 10.0 V.
Threatening under-voltage.
Battery voltage is too low
< 10.4 V.
There is a threat of under-
voltage when heating up
the water.
Battery voltage is too low
< 10.4 V.
Close window.
Charge battery. If necessary replace old battery.
Charge battery.
Charge battery.
After the heater is switched on, the
green LED is lit and the red LED blinks.
Electronics are defective. Please contact the Truma Service Centre.
Approximately 30 seconds after the
heater is switched on, the red LED
is lit.
Gas cylinder or quick-closure
valve in the gas line is closed.
Combustion air infeed or ex-
haust outlet is sealed.
Check gas supply and open valves.
Inspect openings for contamination (slush, ice, leaves, etc.)
and remove contamination if necessary.
After operating for a longer period of
time, the heater switches to failure.
Summer operation with empty
water tank.
Hot-air outlets blocked.
Recirculated air intake
blocked.
Gas pressure regulator
iced up.
Butane content in the gas
cylinder too high.
Switch device off and allow to cool. Fill boiler with water.
Check individual outlet apertures.
Remove blockage from recirculated air intake.
Use regulator heating (EisEx).
Use propane (at temperatures below 10 °C in particular,
butane is unsuitable for heating purposes).
Green and red LEDs flash (with 5 Hz)
after the heating system has been
switched off.
Green LED flashes (with 5 Hz)
after the heating system has been
switched off.
Unit was switched off during
failure. After-running is active
in order to reduce the unit’s
temperature.
After-running is active in
order to reduce the unit’s
temperature.
After-running will switch off after a few minutes. Only at
that time will a failure reset be possible (switch off and then
back on).
No failure. After-running will switch off after approximately
5 minutes.
Water supply
After the heater is switched off, the
drain valve opens (FrostControl).
Temperature at drain valve less
than approx. 3 °C.
Switch the heater on. If the temperature is below approxi-
mately 3 °C, the drain valve will open automatically! If the
heater is not in operation, the drain valve can be reclosed
only when the temperature is approximately 7 °C or higher!
Use heating element for FrostControl.
The drain valve (FrostControl) can
no longer be closed.
Temperature at drain valve is
below approximately 7 °C.
Rotary switch is not at
Operation”.
Switch the heater on. If the heater is not in operation, the
drain valve can be reclosed only when the temperature is
approximately 7 °C or higher!
Turn the drain valve’s rotary switch to “Operation”, then press
the push button until it engages.
Water flows intermittently from the
FrostControl drain muff.
Water pressure too high. Check pump pressure (max. 2.8 bar). If connected to a central
water supply (rural or urban connection), a pressure reducer
must be used, which will prevent pressures higher than
2.8 bar entering the boiler.
If these measures do not remove the failure, please contact the Truma Service Centre.
Trouble-shooting list
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic Combi 6 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info