778975
7
Zoom out
Zoom in
Vorherige Seite
1/39
Nächste Seite
31.01.2022
1312EN EN
3.3. DEVICE USE P1: 10 minute operation / 20 minute pause / 5
rounds,
P2: 20 minute operation / 20 minute pause / 5
rounds,
P3: 40 minute operation / 20 minute pause / 5
rounds.
Operation times / pause and number of rounds
can be freely modied in each of these programs.
Modication of operation time, pause and number
of rounds: Operation times / pause and number
of rounds can be freely modied in each of these
programs. To do this press the “Set” button while in
the program which you wish to modify (P1, P2 or P3).
Starting with P1, press “Set” to move to operation
time setting, the display will show “Set Pro. ON” as
well as blinking operation time setting change it
to your desired value using “Up”/”Down” buttons.
Press “Set” to move to pause time setting, the
display will show “Set Pro. OFF” as well as blinking
pause time setting – change it to your desired value
using “Up”/”Down” buttons. Press “Set” to move to
number of rounds setting. The display will show “Set
Pro. ON OFF” as well as blinking number of rounds.
Use “Up”/”Down” buttons to set your desired value
and press “Set” to move to modication of program
2 (P2). Use the same procedure for the remaining
programmes. To exit programme modications,
press the “Set” button and hold it until the devices
moves to the rst value of previously modied
programme the device will be activated in auto
mode with programme preset operation and pause
time values as well as preset number of rounds.
AIRCLEAN 20G-ECO | AIRCLEAN 5G-WL |
AIRCLEAN 7G-ECO | AIRCLEAN 7G-WL |
AIRCLEAN 10G-WL
Use the operation time selector knob to set the
desired duration of ozonetreatment.
In “HOLD” mode the device will operate continuously.
AIRCLEAN 10G-ECO
Turn the device on using the ON/OFF button located
on the rear panel
Set the desired ozonisation time value using the
ozonisation set knob.
To start continuous operation mode, turn the time
adjustment knob counterclockwise until it reaches
the nal position "HOLD".
Use the ozone control knob to set the ozone level.
The available range is 0-10000 mg/h.
NOTE! Upon completion of treatment ventilate the room
for 15 to 30 minutes. Do not enter the room for at least
2 hours after completion of the ozone treatment. PLEASE
NOTE! Use the device only in empty rooms! Ozone is an
irritant gas, it may cause damage to biological membranes
through radical reactions with their constituents. If the
characteristic ozone smell is still present in the room which
was treated with ozone, rst make sure that the device is
switched o then leave the room and/or ventilate it.
3.4. CLEANING AND MAINTENANCE
a) Always unplug the device before cleaning it.
b) Use only non-corrosive cleaners to clean the surface.
c) Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
d) Do not spray the device with a water jet or submerge
it in water.
NOTE! Do not exceed the “Recommended operation
duration” as indicated in the above tables. Max. continuous
working time and break time for the ozone generators is:
12 hours of work / 12 hours of break.
NOTE! The device operator takes responsibility for safety
measures and operation of the device.
AIRCLEAN 10G | AIRCLEAN 7G | AIRCLEAN 20G |
AIRCLEAN 15G
Continuous operation mode: activate ozone
treatment with ON/O button. The display will show
“HOLD ON”. The device will operate continuously.
Timer mode operation: activate the device with
„Timer” button. The display will show “TIMER OFF
UNTIL” as well as time in hours and minutes until
deactivation of the device. The time can be freely
adjusted in the range between 5 minutes and 24
hours. Timer o modication: upon activating the
device with „Timer” button press “Set” button. Preset
time will start blinking, use “Up”/ “Down” buttons
to set the desired time after which the device is
to deactivate and then press “Set” again the
modication will be stored in the device and the
device will activate.
Auto mode operation: turn the device on with “Auto”
button, the display will show “ON” / device operation
time and program reference number P1, P2 or P3
(switch between programs by pushing the “Auto”
button in sequence). The device is delivered with
three default programs:
Model Recommended operation duration /
treated airspace [m3] in “Auto” mode
P1 P2 P3
10 minute
operation /
20 minute
pause
20 minute
operation /
20 minute
pause
40 minute
operation /
20 minute
pause
AIRCLEAN 7G <100 100–150 150–200
AIRCLEAN 10G <140 140–210 210–280
AIRCLEAN 15G <210 210–315 315–420
AIRCLEAN 20G <280 280–420 420–560
Model Recommended operation duration /
treated airspace [m3]
50 100 150 200 300
AIRCLEAN
7G-ECO 10 min 20 min 30 min 40 min 60 min
AIRCLEAN
20G-ECO 4 min 8 min 12 min 15 min 25 min
AIRCLEAN
5G-WL 20 min 40 min 60 min 80 min 100 min
AIRCLEAN
7G-WL 10 min 20 min 30 min 40 min 60 min
AIRCLEAN
10G-WL 8 min 16 min 24 min 32 min 48 min
Model Recommended operation duration /
treated airspace [m3]
50m3100m3150m3200m3300m3
AIRCLEAN
10G-ECO 8 min 16 min 24 min 32 min 48 min
e) Do not allow water to get inside the device through
vents in the housing of the device.
f) The device must be regularly inspected to check its
technical eciency and spot any damage.
g) Use a soft, damp cloth for cleaning.
h) For an eective use it is suggested to replace the
Ozone Plates every 6 month.
FUSE REPLACEMENT
PLEASE NOTE! The fuse should be replaced by a specialist!
1) Disconnect the device from power supply.
2) Disconnect the power cord and remove the fuse
holder
3) Replace the fuse, making sure that the parameters
are the same.
4) Reinstall the fuse socket.
PLEASE NOTE! To avoid damage to the fuse socket,
do not use excessive force when removing and
installing the fuse socket.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ulsonix AIRCLEAN 10G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info