778975
6
Zoom out
Zoom in
Vorherige Seite
1/39
Nächste Seite
31.01.2022
1110EN EN
f) Do not use the device if the power cord is damaged
or shows obvious signs of wear. A damaged power
cord should be replaced by a qualied electrician or
the manufacturer‘s service centre.
g) To avoid electric shock, do not immerse the cord,
plug or device in water or other liquids. Do not use
the device on wet surfaces.
2.2. SAFETY IN THE WORKPLACE
a) Make sure the workplace is clean and well lit. A
messy or poorly lit workplace may lead to accidents.
Try to think ahead, observe what is going on and use
common sense when working with the device.
b) If you discover damage or irregular operation,
immediately switch the device o and report it to a
supervisor without delay.
c) If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
d) Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
e) In case of re, use a powder or carbon dioxide
(CO2) re extinguisher (one intended for use on live
electrical devices) to put it out.
f) Children or unauthorised persons are forbidden to
enter a work station. (A distraction may result in loss
of control over the device)
g) Regularly inspect the condition of the safety labels. If
the labels are illegible, they must be replaced.
h) Please keep this manual available for future
reference. If this device is passed on to a third party,
the manual must be passed on with it.
i) Keep the device away from children and animals.
j) The room treated with ozone must be sealed (all
external doors closed, gaps in windows, doors etc.
sealed), mechanical ventilation must be switched o
and ventilation grating must be covered. If possible,
internal ventilation should be running in order to
facilitate the air ow in the room treated with ozone.
Open all internal doors in the room treated with
ozone (such as bathroom, cabinet etc.).
k) No humans or animals are allowed in the room
during ozone treatment. If the room must be entered
for any reason, make sure to leave it as quickly as
possible and wear protective clothing as well as
inhalation mask with appropriate cartridge.
l) Smoking, open ame, using tools generating
ame or sparks, using oils or grease or objects
contaminated with oil or grease is not allowed in the
room treated with ozone.
m) Leave the room immediately after activating the
ozone treatment
n) Place the following note or warning plate in front of
/ on the door of the room treated with ozone
REMEMBER! When using the device, protect
children and other bystanders.
2.3. PERSONAL SAFETY
a) Do not use the device when tired, ill or under the
inuence of alcohol, narcotics or medication which
can signicantly impair the ability to operate the
device.
b) The device is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience
and/or knowledge unless they are supervised by
a person responsible for their safety or they have
received instruction on how to operate the device.
c) The device can be handled only by physically t
persons who are capable of handling it, properly
trained, familiar with this manual and trained within
the scope of occupational health and safety.
d) When working with the device, use common sense
and stay alert. Temporary loss of concentration while
using the device may lead to serious injuries.
e) To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
f) The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
2.4. SAFE DEVICE USE
a) Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
o). Devices which cannot be switched on and o
using the ON/OFF switch are hazardous, should not
be operated and must be repaired.
b) Make sure the plug is disconnected from the socket
before attempting any adjustments, accessory
replacements or before putting the device aside.
Such precautions will reduce the risk of accidentally
activating the device.
c) When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
d) Keep the device in perfect technical condition.
Before each use check for general damage and
especially check for cracked parts or elements and
for any other conditions which may impact the safe
operation of the device. If damage is discovered,
hand over the device for repair before use.
e) Keep the device out of the reach of children.
f) Device repair or maintenance should be carried out
by qualied persons, only using original spare parts.
This will ensure safe use.
g) To ensure the operational integrity of the device, do
not remove factory-tted guards and do not loosen
any screws.
h) When transporting and handling the device between
the warehouse and the destination, observe the
occupational health and safety principles for manual
transport operations which apply in the country
where the device will be used.
i) Do not move, adjust or rotate the device in the
course of work.
j) Clean the device regularly to prevent stubborn grime
from accumulating.
k) Do not cover the air intake and outlet.
l) The device is not a toy. Cleaning and maintenance
may not be carried out by children without
supervision by an adult person.
OZONE TREATMENT IN PROGRESS
DO NOT ENTER
1. Handle
2. A light informing that the device is operating
3. Ozone control knob
4. Time set knob
5. Air lter cover
6. Power socket and fuse socket
7. Air lter
8. Power cord
9. ON/OFF button
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40 °C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, reproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
m) It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
n) Keep the device away from sources of re and heat.
o) Do not overload the device.
p) Persons with impaired sense of smell must not use
the device.
q) Provide enough free space around the device before
turning it on. Do not obstruct the ozone vent holes.
r) It is strictly forbidden to directly inhale ozone coming
out of the outlet holes of the device. Inhalation of
high concentrations of ozone over a short period
as well as inhalation of low concentrations of ozone
over a long period of time may cause serious risk to
health or life!
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there
is still a slight risk of accident or injury when using
the device. Stay alert and use common sense when
using the device.
3. USE GUIDELINES
Ozone generator produces ozone from surrounding air.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
AIRCLEAN 10G | AIRCLEAN 7G | AIRCLEAN 20G |
AIRCLEAN 15G
1. air outlet
2. control panel buttons:
On/O – main on/o switch
Auto – auto mode operation
Timer – timer mode operation
Set – access to parameter setting mode
Up – increasing parameter values
Down – decreasing parameter values
3. display
4. remote control – description of buttons: same as
control panel buttons
5. lter
6. fuse socket
AIRCLEAN 20G-ECO | AIRCLEAN 7G-ECO |
AIRCLEAN 5G-WL
1. air outlet
2. operation indicator lamp
3. operation time selector knob
4. fuse socket
5. air lter
AIRCLEAN 7G-WL | AIRCLEAN 10G-WL
1. Air outlet
2. Operation indicator lamp
3. Operation time selector knob
4. power cord connection
5. air lter
AIRCLEAN 10G-ECO
1
2
3
4
5
5
4
12
3
2
1
5
6
3
4
4 3
12
7
6
8
5
9
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ulsonix AIRCLEAN 10G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info