Changing the gas mixture
After immersion, Aladin automatically selects gas 1.
When during an ascent the switch depth is
reached (MOD gas D), an audible warning goes
off and "GAS d", its MOD and O
2
% blink for 30
seconds.
Procedure:
1. Switch to the regulator with gas D and start breathing.
2. Confirm the change by pressing
within 30 seconds. "GAS d" and the
oxygen fraction of gas D is displayed for 5 seconds without blinking.
To interrupt the switch process at any point, press
.
VI Diving with two gas mixtures
Switch depth
WARNING
S
L
O
W
NO
DEPTH
DIVE T IME
Switch to gas D
S
L
O
W
NO
DEPTH
DIVE T IME
Change to gas D confirmed
S
L
O
W
NO
DEPTH
DIVE T IME
4s
Switching process
initiated
Failed or inter-
rupted switch
S
L
O
W
NO
DEPTH
DIVE T IME
No change of gas mixture:
If a diver fails to confirm the change of gas mixture or interrupts the switching
procedure by pressing , Aladin displays "GAS 1", the MOD and the oxy-
gen fraction for 5 seconds. Aladin continues to calculate with gas 1 only and
adapts the decompression calculation accordingly.
If after the decompression calculation has readjusted itself to reflect
the failed switch the diver goes again below the switch depth (MOD
of gas D), Aladin will revert to the decompression calculation that
considers gas D also, since upon ascending again the diver will
have a renewed opportunity to perform the switch once the switch
depth is reached.
Belated change of gas mixture:
A diver can catch up on a required change to gas D until he reaches the sur
-
face.
1. Initiate the switching process by pressing . Aladin displays "GAS d", MOD
and the oxygen fraction of gas D blinking for 30 seconds.
2. Switch to the regulator with the deco gas mixture and start breathing.
3. Confirm the change by pressing
. "GAS d" and the oxygen fraction of
the deco gas is displayed for 5 seconds without blinking. The decompression
calculation will readjust accordingly. (Press to interrupt the switch process
at any time.)
Submerging again after a change to gas D:
If after a change to gas D the Maximum Operating Depth (MOD) of gas D is
exceeded, the ppO
2
max warning will appear ->25.
Change back to gas 1, which is suited for this depth, or rise to the Maximum
Operating Depth of gas D. Failure to do so can result in oxygen poisoning.
1. Initiate the switching process by pressing . Aladin displays "GAS 1", MOD
and the oxygen fraction of gas 1 for 30 seconds.
2. Switch to the regulator with gas 1 and start breathing.
3.
C
onfirm the change by pressing . "GAS 1" and the oxygen fraction of
gas
1
is displayed for 5 seconds without blinking. Afterwards the decompres-
sion calculation will readjust accordingly.
4s
MOD gas d
VI UWATEC Aladin TEC 2G
MOD gas 1
MOD gas d
40
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für UWATEC Aladin TEC 2G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von UWATEC Aladin TEC 2G

UWATEC Aladin TEC 2G Bedienungsanleitung - Deutsch - 54 seiten

UWATEC Aladin TEC 2G Bedienungsanleitung - Holländisch - 54 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info