Local Control This determines whether or not the tone generator of the instrument responds to turning Knobs 1 – 5.
If you set “Local Control” to “off,” the Knobs are internally disconnected from the tone generator.
Even if this is set to “off,” the data will be transmitted via MIDI. Also, the internal tone generator will
respond to messages received via MIDI.
Settings: off (disconnect), on (connect)
Device No.
(Device Number)
Determines the MIDI Device Number. This number must match the Device Number of the DAW
software or the external MIDI device when transmitting/receiving Bulk Dump data, parameter
changes or other System Exclusive messages.
Settings: 1 – 16, all, off
all........................... When this is selected, System Exclusive messages for all MIDI device numbers are received. When
System Exclusive messages such as Bulk Dump are transmitted from the MOTIF-RACK XS with this
setting, the MOTIF-RACK XS is recognized as Device Number 1.
off ..........................When this is selected, System Exclusive messages such as Bulk Dump and parameter change cannot
be transmitted or received. When you try executing transmission or reception of System Exclusive
messages, an error message appears.
Bank Select Sw
(Bank Select Switch)
Determines whether or not Bank Select messages are transmitted or received. When this is set to
“on,” this tone generator responds to incoming Bank Select messages, and it also transmits
appropriate Bank Select messages (when using the panel). When this is set to “off,” Bank Select
messages cannot be transmitted/received.
Settings: off, on
Prg Change Sw
(Program Change Switch)
Determines whether or not Program Change messages are transmitted or received. When this is set
to “on,” this tone generator responds to incoming Program Change messages, and it also transmits
appropriate Program Change messages (when using the panel). When this is set to “off,” Program
Change messages cannot be transmitted/ received.
Settings: off, on
Receive Bulk Determines whether or not Bulk Dump data from the DAW software or the external MIDI devices can
be received.
Settings: protect (not received), on (received)
Controller Reset Determines the status of the controllers (Modulation Wheel, Aftertouch, Foot Controller, Breath
Controller, Knobs, etc.) when switching between voices. When this is set to “hold,” the controllers are
kept at the current setting. When this is set to “reset,” the controllers are reset to the default states
(below).
Settings: hold, reset
If you select “reset,” the controllers will be reset to the following states/positions:
Pitch Bend: Center; Modulation Wheel: Minimum; Aftertouch: Minimum; Foot Controller: Maximum; Foot switch: Off; Ribbon
Controller: Center; Breath Controller: Maximum; Assignable Function: Off; Expression: Maximum; Sustain: Off
Bulk Interval Determines the interval time of the Bulk Dump transmission when the Bulk Dump function is used or
the Bulk Dump Request is received. The Bulk Dump function lets you save the current Voice/Multi
data in the Edit buffer (DRAM) and transmit as Bulk data (System Exclusive message) to the DAW
software on a computer or an external MIDI instrument.
Settings: 0, 10ms, 20ms, 30ms
MIDI Soft Thru
(MIDI Soft Thru Switch)
Determines whether received MIDI data is re-transmitted (as well as via which output) when the
“MIDI In/Out” is set to “MIDI.” If you have not connected a USB cable to the MOTIF-RACK XS, even
if “MIDI In/Out” is set to “USB,” this setting will be available since the MIDI terminal will be
automatically used for transmitting/receiving MIDI data.
Settings: off, on
n If you want to re-transmit received MIDI Clock messages (F8) via the MIDI OUT (Soft Thru) jack, set this parameter
to “on,” and also set the Clock Out parameter (above) to “off” so that transmission of MIDI Clock messages of the
MOTIF-RACK XS is disabled.
Quick Setup When the cursor is located here, pressing the [ENTER] button or the Encoder knob calls up the
Quick Setup dialog (page 101). MOTIF-RACK XS has three combinations of the following parameter
settings as appropriate for basic operations: Local Control, MIDI Sync, Clock Out, Arp MIDI Out Sw.
These combinations can be selected and executed at the Quick Setup dialog, letting you instantly
change all settings depending on your particular application or intended use. The three
combinations can be changed by setting the following parameters in this Utility MIDI window.
QS 1 – 3 Local Control
(Quick Setup 1 – 3 Local Control)
QS 1 – 3 MIDI Sync
(Quick Setup 1 – 3 MIDI Sync)
QS 1 – 3 Clock Out
(Quick Setup 1 – 3 Clock Out)
QS 1 – 3 Arp MIDI Out Sw
(Quick Setup 1 – 3 Arpeggio MIDI
Out Switch)
Changes each parameter settings of the Quick Setup 1 – 3.
Settings:
Local Control ........ off, on
MIDI Sync.............. .internal, external, auto
Clock Out ..............off, on
Arp MIDI Out Sw ...all off, all on
100

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yamaha MOTIF-RACK XS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Yamaha MOTIF-RACK XS

Yamaha MOTIF-RACK XS Bedienungsanleitung - Deutsch - 118 seiten

Yamaha MOTIF-RACK XS Bedienungsanleitung - Holländisch - 118 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info