7. OPERATION
7.1 Self check at power on
After power on the alarm unit checks battery, mains power and telephone-line conditions. If one of these tests fails an
appropriate message will be announced (battery error/power failure/line-check error).
Three beep: Mains power loss AND battery low at the same time!
Quickly handle the announce problem, otherwise the alarm functions are not guarantied.
7.1.1 Detection of wired sensor
EasyAlarm
®
detects the connected motion sensor automatically during the switching on procedure (factory setting). This
sensor is activated for presence verification
Important notes:
By disconnecting the motion detector during the operation mode, an alarm is triggered followed by the
announcement: ”alarm due to sensor 1, sensor failure!”
By connecting the motion detector after the start up procedure of the alarm unit, an alarm is triggered followed by
the announcement: “alarm due to sensor 1, sensor 1 activated!”
7.2 Arm / Disarm system
After power on EasyAlarm
®
automatically arms the system. During operation EasyAlarm
®
can be armed/disarmed
using the remote control or during any telephone connection using DTMF 7 and 9 .
Announce “supervision activated “ or “supervision deactivated”
7.3 Inactive waiting period
7.3.1 After power on or changing position of selection switch (exit delay)
EasyAlarm
®
remains inactive for 20 seconds (LED is on continuously), to leave time to quit your room/house without
triggering an alarm. An emergency call by pressing the emergency button is still possible.
Note:
The entry/exit period can be adjusted according to section 10.3.
If there are unacknowledged alarms, their quantity and the reason of the last alarm will be announced.
If presence verification is activated, following announcement is made: "Presence verification activated".
Key Action
5 Announcement of the monitored functions (inactive waiting period will be restarted)
7
Bypass waiting period and change to inactive supervision mode
Attention: by switching from activated to inactivated supervision mode, an announcement of the
supervision modes is made and the waiting period starts again.
9
Bypass waiting period and change to active supervision mode
Attention: by switching from inactivated to activated supervision mode, an announcement of the
supervision mode is made and the waiting period starts again.
others Test-call will be made to the first calling number
7.3.1.1 Announcement of the supervision functions
The supervision functions can be activated or deactivated individually on each position of the selection switch
EasyAlarm
®
deactivated announcement: "Supervision I/II/III deactivated"
EasyAlarm
®
activated announcement: "Supervision I/II/III
followed by the supervision mode of the activated type of monitoring:
acoustical monitoring announcement: "due to noise"
sensor-1 monitoring announcement: "due to sensor 1”
sensor-2 monitoring announcement: "due to sensor 2”
sensor-3 monitoring announcement: "due to sensor 3” .. “activated”
7.3.2 ..after an successful alarm
EasyAlarm
®
remains inactive for two minutes (LED is on continuously) to avoid too many alarms due to sensor contacts.
An emergency call is still possible during this period. Any key-press results in a test call to the first calling number.
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm CONTROL

EasyAlarm CONTROL Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info