7.7 Phone connection
The colour of the indicator LED changes to orange during telephone connection.
7.7.1 Time-out
There is a timer running in the phone connection mode. Phone connection is kept up for two minutes in case of alarm call,
and ten minutes in case of test call. Ten seconds before disconnection, the called person hears the announcement “abort”.
He/she can restart timer using DTMF 3 at any time.
7.7.2 Announcements
At the beginning of each phone connection the following information will be announced: Individual message followed by
the cause of alarm and the instruction to acknowledge alarm by pressing DMTF 0 . In a Listening-in connection you get
announcement: „to speak press 1“. This announcement is repeated every 8 seconds, until a tone-dialling command is
entered.
Notes:
At the beginning of any phone connection battery state will be checked and announced if low
At the beginning of any phone connection battery state and main voltage are checked. In case a test is negative an
appropriated message will be announced.
The numbers of unacknowledged alarms is announced.
7.7.3 Listening-in connection
Possible tone-dialling commands during the listening-in connection
DTMF => Every valid command will be signalled
0 Terminate phone connection and acknowledge alarm
1 Switching to hands-free mode and restart connection time-out
2 Repeat announcements (Individual message / Cause of alarm)
3 Restart connection time-out (2 minutes)
4 Deactivate output (i.e. switching off alarm siren)
5 Announcement of current supervision mode as well as condition of the output
6 Activate output (i.e. switching on the alarm siren)
7 Change to inactive supervision mode (I, II, III) => monitoring for noise, sensor-1, sensor-2, mains failure and
presence verification inactive. Emergency call and sensor-3 alarm are still possible.
8 Terminate phone connection without acknowledgment
9 Change to active supervision mode (I, II, III) => All monitoring functions re-activated
* * 0 Announcement of calling number sequence
* * n Announcement of calling number n (n = 1..9)
Following tone-dialling command can be used for remote programming, provided the programming is not blocked (
section 10.6)
* * # Trigger an alarm for test reasons Cause of alarm announcement "alarm due to programming"
* * <n> * followed by the new calling number announcement and change of calling number n
* * # # Record individual message => according to section 6.3.1.
7.7.3.1 Use of siren during listening in connection
The activation of a siren ( section 11.2) can be done either manually during a listening-in connection using DTMF 6 or 4
or automatically in accordance to the reason of the alarm ( programming section 10.5.2).
7.7.4 Hands-free connection
The commands during hands-free connection are identical to the commands by listening in connection, except DTMF 1 .
Important note:
Hands-free connection must be terminated using DTMF 0 or 8 . Otherwise a busy tone signal appears until
phone connection is terminated due to time-out.
By selecting hands-free connection an activated siren (optionally) is automatically deactivated. If requested, the
siren can be activated or deactivated by DTMF 6 or 4 .
7.7.4.1 Adjustment of hands-free volume
During hands-free connection you can increase volume by pressing local key #. or decrease by pressing locale key *..
Level can be adjusted in fifteen steps (1dB each) and remains stored.
7.7.5 Acknowledge alarm / Terminate connection
A called party can choose between acknowledgment by pressing DTMF 0 or passing on alarm to next party in calling
number sequence by pressing DTMF 8 .
Important notes:
There is no alarm repetition, if an alarm is triggered by pressing any key of the alarm unit (test call).
An alarm can be confirmed and terminated by pressing key 0. of the alarm unit or by pressing the wireless
emergency button for a second time.
If the alarm is programmed to a pager, the called person can confirm alarm during remote-access after
dialling-in.
7.8 Alarm repetition
If an alarm has not been acknowledged by passing all the calling numbers in the sequence, a number of alarm repetitions
can be programmed ( programming 10.2). Factory setting: two alarm repetitions.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EasyAlarm CONTROL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EasyAlarm CONTROL

EasyAlarm CONTROL Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info