21/24
Under certain conditions, the vent status can be changed (e.g. door opening, cleaning, etc.).
If the vent is closed, the VENT1 icon is off. It is on, if the vent is in the intermediate position, the VENT1
icon flashes
19.2. AUTOMATIC VENT DURING A MANUAL CYCLE
The automatic position of the vent can only be set for a TIME CYCLE, provided that each of the nine timers
is set to a value other than "Inf". To set the automatic position of the vent when a manual cycle is in
progress, proceed as follows.
Press the VENT key when no cycle is running,displays DISPA2 and DISPB2 display the current
settings. More precisely, display DISPA2 shows the advance time of the opening of the vent in
hh:mm, the upper part of display DISPA2 flashes; display DISPB2 shows the setting of the desired
position for the automatic vent "CLS", "HLF" or "OPn" the VENT2 icon flashes.
Press the UP or DOWN keys to change the hours.
Press the TIME key. The lower part of display DISPB2 flashes.
Press the UP or DOWN keys to change the minutes.
Press the TIME key. Display DISPA2 flashes.
Press the UP or DOWN keys to change the position of the automatic vent.
Press the TIME key to end the setting.
Press the ON/OFF key at any time to exit without saving the setting.
Press one of the remaining keys (except TIME, UP and DOWN) or wait for 15 seconds, without
touching the keyboard, to exit the setting and save the settings.
After starting a cycle, you can still change the position of the vent, this operation cancels any automatic vent
setting.
19.3. AUTOMATIC VENT DURING A PROGRAMME
To set the automatic position of the vent when a manual cycle or programme is in progress, proceed as per
the manual cycle. The automatic vent can be set for each timer phase as long as the timer setting is anything
other than "InF" and "Hold".
20. CYCLE END
Once the cycle is complete, the buzzer emits a sound for 15 seconds. Press any key to silence the buzzer.
To stop a cycle, press the START/STOP key for at least one second. The buzzer emits a continuous sound.
21. SELECTING A CLEANING CYCLE
The cleaning cycle is always available. There are three cleaning programmes “CL1“,“CL2“,“CL3“ and a detergent
pump loading programme “Chr”.
A cleaning cycle can be selected only in OFF mode.
Press the PROGRAMS key. The display DISPA1 shows the "Cln".
Press the UP or DOWN keys to select the program.
Press the START/STOP key to start the program.
There are three cleaning programs and one detergent pump filling program (the display DISPB2 shows the "Chr"
label).
The cleaning programs are fixed and cannot be modified during the cycle selection phase.
The cleaning programs can be modified only if the dedicated programs are modified via the parameter
configuration procedure.
22. RUNNING A CLEANING CYCLE
During the running of a cleaning cycle: