538730
28
Zoom out
Zoom in
Vorherige Seite
1/132
Nächste Seite
The learned force setting must be checked using a 2.
suitable force measuring device to make sure that the
values are permissible within the application scope of the
European Standards EN 12453 and EN 12445 or the
corresponding national regulations.
5.6 Changing the starting point for slow speed
when opening and closing
The slow speed length is automatically set to a basic value of
approx. 500 mm before the end positions after the end
positions have been learned. The starting point can be
reprogrammed from a minimum length of approx. 300 mm up
to the entire gate length (see Figure 7.2).
Setting the positions for slow speed:
The end-of-travel positions must be set and the gate is in 1.
the CLOSE end-of-travel position.
DIL switch 2 must be OFF.2.
Set 3. DIL switch 12 to ON to set the starting position for
slow speed.
Press print button 4. T.
The gate will travel normally in press-and-release
operation towards the OPEN direction.
When the gate passes the required position for the start 5.
of slow speed, briefly press print button P.
The gate will move at slow speed for the remaining
distance until in the OPEN end-of-travel position.
Press print button 6. T again.
The gate will again travel normally in press-and-release
operation towards the CLOSE direction.
When the gate passes the required position for the start 7.
of slow speed, briefly press print button P.
The gate will move at slow speed for the remaining
distance until in the CLOSE end-of-travel position.
Set 8. DIL switch 12 to OFF.
The slow speed starting point settings have now been
completed.
NOTE:
The starting points for slow speed can also be set to
"overlap"; in this case, the entire leaf movement is in slow
speed.
Changing the starting points for slow speed deletes the
already learned forces. After a change has been made, the
green LED flashes to signal that the forces must be learned
again.
Both of the following procedures must be conducted f
three times.
Learning the forces to the OPEN end-of-travel position:
Press print button f T once.
The operator automatically moves into the OPEN end-of-
travel position.
Learning the forces to the CLOSE end-of-travel position:
Press print button f T once.
The operator automatically moves into the CLOSE end-
of-travel position.
5.7 Reversal limit
During operation of the gate in the CLOSE direction, it must
differentiate between two options: whether the gate contacts
the limit stop (gate system stops) or an obstruction (gate
reverses direction). The limit range can be adjusted as follows
(see Figure 7.3).
Setting the reversal limit:
Set DIL switch 111. to ON.
The reversal limit can now be set step-by-step.
Briefly press print button 2. P to reduce the reversal limit.
or
Briefly press print button T to increase the reversal limit.
During the procedure to learn the reversal limits, the
green LED displays the following settings:
1x flashing Minimum reversal limit, the green LED
flashes once
to
10x flashing Maximum reversal limit, the green LED
flashes max. 10 times
Set DIL switch 113. back to OFF to store the set reversal
limit.
5.8 Overview and settings of the DIL switches
Changes to the DIL switch settings are only permissible under
the following conditions:
The operator is at a standstill.•
The advance warning or hold-open phase is not active.•
The DIL switches must be set as described below in
accordance with national regulations, the desired safety
devices and the on-site circumstances.
DIL switch 15.8.1
Installation direction:
See Chapter f Preparation, page 26
DIL switch 25.8.2
Installation direction:
See Chapter f Learning the gate‘s end-of-travel positions,
page 26
5.8.3 DIL switch 3/DIL switch 4
SE 1 safety device (opening):
See f Figure 7.4
The functions of the safety device are set with DIL switch 3 in
combination with DIL switch 4.
3 ON Activation kit for closing edge safety device or
photocell with testing
3 OFF
8k2 resistance contact strip•
No safety device (8k2 resistance between •
terminals 20/72, delivery status)
4 ON Brief, delayed reversing in the CLOSE direction
(for photocell)
4 OFF
Brief, immediate reversing in the CLOSE direction
(for SKS)
28
TR10A059-C RE / 10.2008
ENGLISH
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hormann Schuifhekaandrijving wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info