Mixer Reference
Auto Automatic selection. Valid for Internal and Digital clock sources.
13.5MHz – 13.5MHz video dot clock. Valid for External and Header clock
sources.
27MHz – 27MHz video dot clock. Valid for External and Header clock
sources.
Word Word clock. Valid for External and Header clock sources.
Word256 – 256 times word clock. Valid for External and Header clock sources.
Rate – Displays the current sample clock rate of the LynxONE. When the Sample
Clock Source/Reference are set to Digital/Auto, External/Word, External/
Word256, Header/Word, or Header/Word256 the displayed sample rate must
match the rate of the incoming clock being used for synchronization. This
will ensure the correct sample rate is stored in the file’s WAV header, and that
audio will playback at the correct sample rate.
Auto Selection – Enables automatic recall of the Sample Clock Source after the
digital input is used for recording or monitoring. When an application using
the Digital In device starts recording, or the Monitor Source is set to Digital
In, the Sample Clock Source is automatically switched to Digital. When Auto
Selection is on, the Sample Clock Source will be reset to it’s previous state
when an application using the Digital In device stops recording or the Monitor
Source is set back to Analog In. When Auto Selection is off, the Sample Clock
Source will not be reset to it’s previous state. In this mode the user must
manually select a different Sample Clock Source, if required, after using the
digital input for monitoring or recording.
Digital Format Allows selection of either AES/EBU or S/P DIF formats for Digital
In and Digital Out.
Trim – Sets the nominal analog input and output levels for the LynxONE to either
+4dBu or -10dBV.
Monitor SourceAllows selection of Analog In, Digital In, Analog Out or Digital
Out as the monitor source. NOTE: When the Monitor Source is set to Digital In,
the Sample Clock Source is forced to Digital in order for the LynxONE to lock to
the incoming digital signal. In this mode, the Mixer will not respond to changes
to the Sample Clock Source. If Auto Selection is enabled, the Sample Clock Source
will return to its previous setting when the Monitor Source is changed from Digital
In to Analog In. Please refer to the Auto Selection description.
Levels – Enables or disables peak meter calculations. Levels are enabled when checked.
Peak Meter values are calculated in real-time by the driver based on the audio
currently being played or recorded by the LynxONE. Although this is done very
quickly, disabling this function will free the system processor slightly.
Calibrate Converters – Used to calibrate DC offset of the A/D and D/A converters.
When the LynxONE driver first loads, the converters are calibrated for optimum
fidelity. Over time temperature changes inside your computer may cause the DC
offset to drift slightly. Because of this, Lynx recommends recalibration 15 to 30
minutes after your computer has been turned on and whenever significant changes
in room temperature occur.
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lynx ONE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info