English - 27
English
Setting the temperature control
6. Check the temperature in the coldest room.
7. Set the firing characteristic using the CH menu when the
temperature in the coldest room is too cold or too warm
(refer to paragraph 6.2). For example, if it is too cold or too
warm in a room during winter, the firing characteristic can be
adjusted according to the following diagram.
Outside temperature is less then 0 °C:
Warmer: raise the end point of the firing characteristic
Colder: lower the end point of the firing characteristic
Outside temperature is between 0 °C and 10 °C:
Warmer: raise the starting point as well as the end point of the
firing characteristic
Colder: lower the starting point as well as the end point of
the firing characteristic
Outside temperature is above 10 °C:
Warmer: raise the starting point of the firing characteristic
Colder: lower the starting point of the firing characteristic
8. Continue setting the hot water supply; refer to chapter 7.
If floor heating is used, we recommend to reduce the maxi-
mum temperature of the CH water.This can be obtained with
the UBA of the boiler. Reducing the maximum temperature of
the CH water prevents too hot water in the floor heating.