English - 31
English
Setting the hot water supply
7. Setting the hot water supply
This chapter is only necessary if the boiler also supplies hot
water.
If the hot water supply is set to automatic (refer to chapter 4),
the thermostat takes care that the water in the boiler will only
be heated during the day. With the ‘advanced hot water heat-up’
and the ‘hot water stop delay’, the start and stop points for
heating the water can be set:
- The advanced hot water heat-up determines how long before
the switching point from ECO to another temperature in the
clock program the boiler starts heating the boiler water.
- The hot water stop delay determines how long after the
switching point to ECO in the clock program, the boiler stops
heating the boiler water.
If advanced heat-up is set to on (refer to chapter 6), the
advanced hot water heat-up starts heating the hot water,
calculated from the moment, the CH installation starts
advanced heating up the house.
7.1 Checking and/ or changing the settings
- Check with the hot water menu (refer to paragraph 7.2)
whether the advanced hot water heat-up is set correctly.
Change the advanced hot water heat-up if necessary.
- Check with the hot water menu whether the hot water stop
delay is set correctly. Change the hot water stop delay if necessary.
- Leave the hot water menu.
The IRT 30 thermostat is now ready for use.