21. Place of installation
-Set up the compressor on an even surface.
22. Supply hoses at pressures above 7 bar should be
equipped with a safety cable (e.g. a wire rope).
23. Use flexible hoses in order to prevent transmitting unac-
ceptable loads to the pipeline system at the connection
between the compressor system and the pipeline system.
24. It is essential to use separators, traps and drains which
process the liquids produced by the compressor before
the compressor system is put into operation.
Warning! This electric tool generates an electromagnetic field
during operation. This field can impair active or passive medical
implants under certain conditions. In order to prevent the risk
of serious or deadly injuries, we recommend that persons with
medical implants consult with their physician and the manufac-
turer of the medical implant prior to operating the electric tool.
Additional Safety Instructions
Safety instructions for working with compressed
air and blasting guns
The compressor pump and lines can become very hot during
operation. Touching these parts will burn you.
The air which is sucked in by the compressor must be kept
free of impurities that could cause fires or explosions in the
compressor pump.
When releasing the hose coupling, hold the hose coupling
piece with your hand. This way, you can protect yourself
against injury from the rebounding hose.
Wear safety goggles when working with the blow-out pistol.
Foreign bodies or blown off parts can easily cause injuries.
Do not blow at people with the blow-out pistol and do not
clean clothes while being worn. Risk of injury!
Safety information for paint spraying
• Do not process any paints or solvents with a flash point be-
low 55 °C. There is a risk of explosion!
Do not heat up paints or solvents. There is a risk of explosion!
If hazardous liquids are processed, wear protective filter
units (face guards). Also, adhere to the safety information
provided by the manufacturers of such liquids.
The details and designations of the Ordinance on Hazard-
ous Substances, which are displayed on the outer packaging
of the processed material, must be observed.
Additional protective measures are to be undertaken if neces-
sary, particularly the wearing of suitable clothing and masks.
Do not smoke during the spraying process and/or in the
work area. There is a risk of explosion! Paint vapors are eas-
ily combustible.
Never set up or operate the equipment in the vicinity of a fire
place, open lights or sparking machines.
Do not store or eat food and drink in the work area. Paint
vapors are harmful to your health.
• The work area must exceed 30 m3 and sufficient ventilation
must be ensured during spraying and drying. Do not spray
against the wind. Always adhere to the regulations of the
local police authority when spraying combustible or hazard-
ous materials.
Do not process media such as white spirit, butyl alcohol and
methylene chloride with the PVC pressure hose. These media
will destroy the pressure hose.
Operating pressure vessels
• You must keep your pressure vessel in good working order,
operate the vessel correctly, monitor the vessel, carry out
necessary maintenance and repair work immediately and
meet the relevant safety precautions.
The supervisory authority may enforce essential control
measures in individual cases.
• A pressure vessel is not allowed to be used if it has faults or
deficiencies that can endanger workers or third parties.
Check the pressure vessel for signs of rust and damage each
time before using. Do not use the compressor with a dam-
aged or rusty pressure vessel. If you discover any damage,
then please contact the customer service workshop.
Do not lose these safety instructions.
Residual risk
Observe the specified maintenance and safety instructions in
the instruction manual.
Always be attentive at work and keep third persons at a safe
distance from your workplace.
Even with proper use of the device, a certain residual risk re-
mains, which can not be excluded. The following potential haz-
ards can be derived from the type and design of the device:
Unintentional commissioning of the product
Hearing loss if no suitable hearing protection is worn
Wear safety glasses to prevent your eyes and face from
dust and dirt particles
Inhalation of whirled-up dust and dirt particles
6. Technical data
Mains connection ........................................220-240 V~ 50 Hz
Motor rating W ...................................................................1800
Operating mode .......................................................................S1
Compressor speed .....................................................2850 min-1
Pressure vessel capacity (in liters) .............................approx. 24
Operating pressure .............................................approx. 10 bar
Theoretical intake capacity (l/min) ........................ approx. 260
Sound power level LPA ...............................................75.2 DB(A)
Sound power level LWA .............................................. 95.2 dB(A)
Uncertainty KPA/WA ...........................................................2.11 dB
Protection type .......................................................................IP20
Weight of the unit in kg ..............................................approx. 27
Oil (15W 40) l .......................................................approx. 0.25
Max. altitude (above mean sea level) ...........................1000 m
The noise emission values were measured in accordance with
EN ISO 3744:2010.
Wear hearing protection.
The effects of noise can cause a loss of hearing.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Parkside PKO 270 A5 - IAN 315462 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Parkside PKO 270 A5 - IAN 315462

Parkside PKO 270 A5 - IAN 315462 Bedienungsanleitung - Deutsch, Englisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info