6 5110757E OI II Webasto Pure
NOTE
In some countries, single-phase charging is limited to
a defined current. The local connection requirements
must be observed.
All protective devices specified below must be designed
such that the charging station is disconnected from the
grid in the case of a fault. You must meet national install-
ation regulations and standards when selecting the pro-
tective device.
8.2.1 Dimensioning of the Residual Current
Circuit Breaker (RCCB)
The national installation regulations generally apply. Un-
less otherwise specified therein, each charging station
must be protected by an appropriate residual current
device (RCD type A) with a trip current of ≤30mA.
8.2.2 Dimensioning of the circuit breaker
The circuit breaker must conform to IEC 60898. The let-
through energy (I²t) must not exceed a maximum 80,000
A²s.
Alternatively, a residual current circuit breaker combina-
tion (RCBO) according to EN 61009-1 can be used. The
aforementioned parameters apply for this circuit breaker
combination.
8.2.3 Mains isolation device
The charging station does not have its own main ON/OFF
switch. The protective devices installed in the power sup-
ply system are therefore also used to disconnect the
power supply.
8.3 Installation
See also chapter15, "Assembly" on page 9. The sup-
plied installation material is intended for mounting the
charging station on a concrete wall or on an external
stand. For installation on a stand, the mounting material
is included in the scope of delivery of the stand.
üScope of delivery is checked for completeness.
uTake into account the mounting position at the install-
ation location. See Fig. 14.
NOTE
The central hole must be drilled!
uRemove the drill template at the perforation from the
packaging.
uMark the four positions of the drill holes at the install-
ation location using the drill template. See Fig. 14.
uDrill 4 holes of Ø 8mm in the marked positions.
uPosition the bracket over the upper holes and mount
using 2 wall plugs and 2 screws, 6x70mm, T25.
uRemove the lower cover from the connection area of
the charging station.
Fig.8
uRemove the spiral antikink protection from the con-
nection area of the charging station and place it with
the other supplied material.
uFor surface mounting, make a recess for routing the
lead on the back of the charging station using the des-
ignated lateral predeterminedbreakingpoints (if ne-
cessary deburr the edge of the break using a round
file).
uInsert the lead through the designated lead-through
and fit the charging station on the previously mounted
bracket.
uMount the charging station using 2 screws,
6x90mm, T25 using the mounting holes in the lower
connection area. Do not exceed the max. torque of
6Nm.
8.3.1 Connecting the charging cable
uPush the spiral antikink protection with the threadless
opening forward over the supplied charging cable.
uGuide the charging cables through the previously pre-
assembled sealing clip.
NOTE
Ensure correct fit of the previously pre-assembled rub-
ber seals in the sealing clip.
uPush the charging cable at least 10mm beyond the
upper edge of the clamping area of the strain relief
clamp.
uTurn the antikink protection spiral several turns onto
the sealing clip.
NOTE
Do not tighten yet.
Fig.9
uScrew in the supplied strain relief clamp in the correct
position on the charging cable.
NOTE
The strain relief clamp has two position options for
charging cable versions 11kW and 22kW.
Ensure that the “11 kW installed” label for an 11 kW
charging cable is visible.
uFit the strain relief clamp in the correct mounting posi-
tion using the supplied self-tapping Torx screws
(6.5x25mm) and tighten to 5.5Nm. (Attention: Do
not overtighten screws).
uThe strain relief clamp must be flush when securely
screwed in.
NOTE
Perform a tension test on the charging cable to make
sure that the cable cannot move.
uScrew the antikink protection spiral onto the sealing
clip with a torque of 4Nm.
uUsing the slot-head screwdriver (3.5 mm), connect the
individual cable ends according to the specification in
the illustration on the right terminal block with the
"out" label.
uTo do this, insert the screwdriver in the designated up-
per opening of the spring relief for the terminal block
and open the clamping spring.
uNow insert the individual wire into the designated
connection opening of the terminal block (lower open-
ing).
Charging cable Description
Blue N
Brown L1
Black L2
Grey L3
Yellow-green PE
Black-white Control cable (CP)
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Webasto Pure II wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info