If setting the DIP1 & DIP2 to ‘Off’, only the internal contact will be active.
When two contacts are in use for internal and external connection simulta-
neously, one activation will be counted if one of the contacts is opened; while
both contacts must be all close, the Detector will then be treated as close.
3. If external contacts are wired to the Detector, set the DIP1 to ‘Off’ and DIP2
to ‘On’.
IMPORTANT: If external contacts are not connected, set the DIP1 to ‘On’ and
DIP2 to ‘Off’ for the detector to operate correctly.
4. In order to communicate with the Control Panel, the ID code of the Detector
needs to be learned by the Control Panel. By pressing the tamper switch
either located adjacent to the PCB or rear cover of the Detector will emit the
ID code to the Control Panel instantly, subject to the Control Panel being set
at the Zone setup mode.
TESTING THE MAGNETIC CONTACT DETECTORS
Ensure that the system is in Test Mode
1. Use the and buttons to scroll through the menu until ‘WALK TEST
is displayed.
Press to activate Walk Test. ‘Walk Test Waiting…’ will be displayed.
2. Remove the battery cover by sliding off.
As the battery cover is removed the LED on the Detector will illuminate for
approx. 1 second to indicate that the tamper switch has been activated.
In addition, the Control Panel will beep to indicate that an alarm signal has
been received and ‘Magnetic Contact Tamper’ will be displayed.
3. Open the door/window to detach the magnet from the Detector. As the
magnet is parted from the detector the LED will illuminate for approx. 1
second to indicate that the Detector has been triggered. In addition, the
Control panel will beep to indicate that an alarm signal has been received and
the identity of the zone that the detector is set for will be displayed.
Note: In normal mode with the battery cover fitted, the LED on the detector
will not illuminate when the detector is triggered, (unless the battery is low).
4. If connected, operate the wired Magnetic Contact. As the contact is opened
the LED on the Detector should illuminate for 1 second to indicate that it has
been triggered and the Control Panel will acknowledge the alarm signal.
5. Refit the battery cover on the Detector.
6. Press to return to the top level menu of TEST MODE.
REMOTE TELEPHONE CONTROL
Scroll through the manual until :1 Remote TEL Control’ is displayed and
press .
Default setting: OFF
To change the setting press .
Press to enable the Remote Telephone control, or
Press to disable the Remote Telephone control.
NUMBER OF DIALING CALL
This facility controls the number of dialing call via the connected telephone line.
Default setting: one call
Scroll through the manual until :2 Remote Type’ is displayed and press .
To change the setting press .
Scroll through available options (e.g. one call & double call) until the required
setting is displayed.
ONE CALL
The number of ring for the Control Panel must be greater than that of the set
number of rings. By doing so, the Control Panel will answer the call and emit
three beeps on the phone line to prompt for a User Password to be entered
using the telephone keypad.
DOUBLE CALL
This feature is suitable for use when the fax or answer phone is connected to
Control Panel externally. The procedure is as follows:
1. Dial up the system and hang up after two rings.
2. Redial up the system within 28s as maximum (14s as minimum), subject to
the interval of ring being entered at 13s, the system will pickup the phone
after 1 ring.
Note: The maximum and minimum period for redialing up the system will
vary depending on the interval of ring you entered. Refer to ‘INTERVAL OF
RING FOR DOUBLE CALL’ for better comprehension.
3. Enter the User Password as normal.
NUMBER OF RINGS FOR ONE CALL
The number of rings for one call must be set within 2-9
ENEN
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elro HA68S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elro HA68S

Elro HA68S Kurzanleitung - Deutsch - 1 seiten

Elro HA68S Bedienungsanleitung - Deutsch - 34 seiten

Elro HA68S Kurzanleitung - Englisch - 1 seiten

Elro HA68S Kurzanleitung - Holländisch - 1 seiten

Elro HA68S Bedienungsanleitung - Holländisch - 34 seiten

Elro HA68S Kurzanleitung - Französisch - 1 seiten

Elro HA68S Bedienungsanleitung - Französisch - 34 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info