Installation manual: Oasis security system JA-80K - 7 - MKE51801
control panel twice but to two different addresses with different
features –see 12.40.
Only a single device can be enrolled to each address.
When indicator A lights, it means the displayed address is
occupied and therefore no more devices can be enrolled to
this address.
If a device has already been enrolled to an address, and it is
then re-enrolled to another address, the device’s address
assignment will change from the original address to the new
one.
If a device cannot be enrolled to the control panel, either it
does not have a good wireless connection to the control panel
possibly due to excessive distance or it could be too close to
the control panel (closer than 2 meters is not permitted),
To re-enroll a device, first disconnect its battery. Then wait
about 10 seconds or, to save time, press and release its
tamper switch to quickly discharge any remaining energy.
A sub-control panel can be enrolled to a master control
panel by keying in the sequence 299 on the keypad of the sub
control panel which must be in Service mode. (see 12.10),
If you intend to use final-door detectors in the system, they
must be enrolled to addresses 01 to 05 or 46 to 50 (see
12.23).
11.3. Testing enrolled devices
1. The control panel must have its antenna connected and be
in Service mode. If not in Service mode, then key in 0
service code (factory-default 8080). To enter Service mode
the control panel must be initially unset (disarmed).
2. Trigger the device to be tested (if it is a detector close its
cover first and then wait until it is ready for testing).
3. The keypad will beep and display a description of the signal
received from the device under test (the keypad cover
should be flipped open). We recommend technicians to
carry the wireless keypad around while testing to ease the
process.
Notes:
Motion detectors JA-80P and JA-85P can be tested for a
maximum of 15 minutes after closing their covers. After this
period the detector will ignore frequent movements (see
detector manuals for details).
Devices can also be tested in maintenance mode – see 13.4.
11.4. Measuring signal strength
1. The control panel must have its antenna connected and be
in Service Mode. If it is not, then enter 0 service code
(factory default: 8080). The control panel must be unset
(disarmed) to enter Service Mode.
2. Key in 298, and the lowest enrolled address will be
displayed.
3. Trigger the device enrolled to the displayed address. The
keypad display will show the received signal strength on a
scale of 1/4 to 4/4. Keep the keypad cover flipped open
while measuring signals.
4. Other addresses for devices can be selected using the
arrow keys to measure their signals too.
5. Exit signal measuring by pressing the # key.
Notes:
Motion detectors JA-80P and JA-85P can be tested for a
maximum of 15 minutes after closing their covers. After this
period the detector will ignore frequent movements (see
detector manuals for details).
Measuring the signals from a JA-80L internal siren can be
activated by pressing its button. A JA-80A outdoor siren can
be activated for signal strength measurement by opening its
cover thereby triggering its cover tamper switch.
Each installed device should have a minimum signal strength
of 2/4. If the signal is too weak, the device should be relocated
or a higher control panel sensitivity can be selected. (see
12.36) Alternatively the control panel can be equipped with an
external antenna (see 10).
This measurement shows the quality of the signal received
from the device at the control panel.
The wireless keypad can be carried during installation or
testing by disabling its tamper contact via the jumper near the
tamper contact – do not forget to re-enable the tamper before
finishing the installation – Note: the keypad usually has a
slightly shorter working range than the detectors. Therefore, if
carried to more-distant detectors the triggering of the
detectors might not be shown.
The most convenient way of measurement is via a computer
running ComLink SW.
11.5. Erasing enrolled devices
1. The control panel must be in Service Mode. If it is not, then
enter 0 service code (factory default: 8080). The control
panel must be unset (disarmed) to enter Service Mode.
2. Key in “1” to enter enrollment mode and using the arrow
keys select the desired address of the device you wish to
erase.
3. Press and hold the “2” key until a beep is heard and the A
indicator turns off.
4. After all the desired devices have been erased, press #.
Notes:
To erase all wireless devices, press and hold the “4” key in
enrollment mode.
If a wireless keypad is erased, it will stop communicating with
the control panel and must be re-enrolled before being used
again. (see 7.1).
11.6. Enrolling the control panel to UC and AC
modules
If you wish to use UC and AC modules to output PGX and PGY
signals, you must enroll the control panel to these modules as
follows:
1. The control panel must be in Service Mode. If it is not, then
enter 0 service code (factory default: 8080).
2. On the UC or AC module, enter the desired enrollment
mode (see the manual of the particular module)
3. Key in 299 on the control panel keypad and check that all
LEDs on the module flash a few times to confirm successful
enrollment.
Notes:
Because the UC and AC modules have rather short
enrollment-period timeouts, we recommend locating the
module close to the control panel during enrollment.
Alternatively you could carry the wireless keypad close to the
module to perform enrollment.
The control panel can be enrolled to the desired number of
UC/AC modules to control multiple PG outputs in an
installation.
Each UC and AC module has 2 relays, X and Y which have to
go through enrollment separately. The X relay reacts to PGX
signals from an enrolled control panel and the Y relay reacts
to PGY signals from an enrolled control panel. The control
panel’s PGX signal can be enrolled to the X relay and the
control panel’s PGY signal can be enrolled to the Y relay.
Therefore, the enrollment procedure has to be done twice if
both relays are to be controlled by the control panel’s PG
signals.
Only one control panel can be enrolled to a UC or AC receiver
because a control panel repeats its PG signals every 9
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Jablotron JA-80K wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Jablotron JA-80K

Jablotron JA-80K Bedienungsanleitung - Englisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info