the nose. To increase the efficacy of the
therapy, hold your breath for a while after
having inhaled.
During the treatment, remain quiet and
relaxed. Breathe regularly and not too
quickly. If you wish to interrupt the
inhalation shortly, remove the mask for a
while and then place it again on nose and
mouth.
7) Connect the transformer to the device and then
to the power supply plug paying attention that
the voltage is right.
8) Switch on the device pressing the ON/OFF key.
Make sure that the warning light switches on
(blue colour).
During inhalation, the device must
compulsorily remain in vertical position: this
assures its correct operation, as well as the
maximum efficacy of therapy.
Immediately interrupt the treatment if you feel
unease during the aerosol-therapy.
9) The device is equipped with an automatic
stop device that disables the device when the
drug is almost finished. You can switch off the
device in any moment by pressing the ON/OFF
switch.
IMPORTANT:
As with most equipment for aerosol therapy,
at the end of the inhalation treatment, a certain
amount of the pharmaceutical will remain in
the nebulization ampoule: this is perfectly
normal. This amount of pharmaceutical,
also know as residual volume, cannot be
nebulized.
10)Let the device cool down for some minutes,
turn the device upside down or use an
absorbing cloth to remove the residual
liquid and perform the cleaning procedures
according to paragraph “Cleaning and
maintenance”.
REPLACEMENT OF THE
PHARMACEUTICAL AMPOULE
For more efficient treatment, substitute the
medicine cup after every inhalation cycle.
Within the pack you will find ampoules which you
can use for replacement purposes.
Other ampoules can be purchased from your
retailer.
MICROBIC CONTAMINATION
In the presence of conditions carrying the risk of
microbial infection and contamination, personal
use of the accessories only is advised (always
consult a doctor).
CLEANING
1) Caution! Hot surface!
Before cleaning the device, let it cool
since the transducer heats during the
use.
2) After having disconnected the socket, remove
the cover and empty the tank from any
eventual residuals.
3) Clean the cover of the device without
disassembling it in any part with a cloth
moistened with water or vinegar, so that all
residuals are removed.
4) Clean the external part of the device using
a soft cloth soaked with water and neutral
soap (do not clean the main unit by
placing it under running water and pay
attention that no liquid penetrates into
the device).
5) In case of daily use, it is suggested to disinfect
or sterilize the accessories all the days to limit
the risk of infections.
In this case, place all acces sories, except for
the air connection tube, in boiling water for
10 minutes and then let them dry completely
before reusing them.
6) Disinfect or sterilize all components, except
for the air connection tube, in boiling water
for 10 minutes also before using the device
for the first time.
7) To disinfect the device, it is also possible to
use 70% alcohol (or a disinfecting spray with
alcoholic base).
Check that within the device there are not
residual parts of the disinfectant.
8) The device, the tank and all accessories must
be completely dry before using them.
9) Store the device in a fresh and dry place.
TECHNICAL SPECIFICATIONS
•Powersupply:AC230V/DC13,5V
• Operatingconditions:
Temperature: min. 5°C; max. 45°C
Relative humidity: less than 85%, in absence
of condensate
• Storingconditions:
Temperature: 0°C; 65°C
Relative humidity: less than 95%, in absence
of condensate
•Ultrasoundfrequency:1.7MHz
•Nebulizationcapacity:about0.4ml/minute
•Percentageofaerosoloftheinhalation:60%
of the particles < 5 µm
•Mediumsizeoftheparticles:3.4µm
•Maximumvolumeoftheinhalingproduct:
max. 8 ml = 8 cc
•Size:235x145x285mm
•Weight:350g
Device of BF type
Device of second class
Caution: check the instructions for use
DISPOSAL PROCEDURE
(DIR. 2002/96/EC - WEEE)
The symbol on the bottom of the device
indicates the separated collection of
electric and electronic equipment.
At the end of life of the device, do not
dispose it as mixed solid municipal waste,
but dispose it referring to a specific collection
centre located in your area or returning it to the
distributor, when buying a new device of the same
type to be used with the same functions.
This procedure of separated collection of
electric and electronic devices is carried out
forecasting a European environmental policy
aiming at safeguarding, protecting and improving
environment quality, as well as avoiding potential
effects on human health due to the presence of
hazardous substances in such equipment or to an
improper use of the same or of parts of the same.
Caution! The wrong disposal of electric and
electronic equipment may involve sanctions.
WARRANTY
This equipment is covered by a 2-year warranty
elapsing from the purchase date, which has to be
proven by means of the stamp or signature
of the dealer and by the fiscal payment
receipt that shall be kept enclosed to this
document. This warranty period complies with
the laws in force (Italian legislative decree No. 24
dated Feb. 02, 2002 and following “Consumers’
Act” Italian legislative decree No. 206 dated Sep.
03, 2005) and applies only in case the consumer
is a private entity. Laica products are designed
for domestic use; therefore, their use in public
businesses is forbidden.
The warranty covers only production defects and
is void, if the damage is caused by accidental
events, wrong use, negligence or improper use
of the product. Use the supplied accessories
only; the use of other accessories may lead to
warranty voidness. Do not open the equipment
for any reason whatsoever; in case of opening
or tampering of the equipment, warranty decays
definitively.
Warranty does not apply to parts subject to tear
and wear along the use, as well as to batteries,
when they are standard supplied.
Warranty decays after 2 years from the purchase
date. In this case, technical service interventions
will be carried out against payment. Information
on technical service interventions, under warranty
terms or against payment, may be requested by
writing at info@laica.com.
Nothing shall be owed for the repairing or
replacement of products covered by the warranty
terms. In case of faults, refer to a dealer; DO NOT
send anything directly to LAICA.
All interventions covered by warranty (including
product replacement or the replacement of any
of its parts) shall not be meant to extend the
duration of the original warranty period of the
replaced product.
The manufacturer cannot be made liable for any
damages that may be caused, directly or indirectly,
to people, things and pets resulting from the
inobservance of the provisions contained in the
suitable user manual, especially with reference
to the warnings related to installation, use and
maintenance of the equipment.
Being constantly involved in improving its own
products, Laica reserves the right to modify its
product, totally or partially, with reference to any
production need, without that this involves any
responsibility whatsoever by Laica or its dealers.
Instructions and warranty
English
GB
English
ULTRASOUND AEROSOL THERAPY DEVICE
GB
1514
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Laica MD6026 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info