CA-10 Installer Manual 5
the source). It is also possible to indicate (in the output options) the partition the output is associated
with. If this is the case, the zone alarms will be limited to those from the zones belonging to the
partition indicated. When the "list of outputs" is empty and no partitions are indicated, the output reacts
to all alarms (except for the fire alarms).
The output can remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or
until the alarm is cleared by the user. During its operation, it can every second change its state
(pulsate).
2 fire/burglary alarm the output starts on detecting by the control panel of a burglary alarm
(continuous signal) and/or a fire alarm (intermittent signal). The output operation can be limited to the
indicated "list of outputs" or a specific partition (identically as for the 1 output type). The output can
remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is
cleared by the user.
3 fire alarm the output starts when the control panel detects a fire alarm. Such an alarm is triggered by
fire zones or the user (through the FIRE ALARM function). The output operation can be limited to the
specified "list of outputs" or particular partitions (identically as for the 1 output type), indication of any
zones other than the fire ones having no sense, as they would not generate a fire alarm. The output
can remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the
alarm is cleared by the user. During operation, it can every second change its state (pulsate).
4 keypad alarm the output starts on detecting any keypad alarm (FIRE, PANIC, AUX., keypad tamper
alarms). The output operation can be limited to the alarms from specified partitions. The output can
remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is
cleared by the user. During its operation, it can every second change its state (pulsate).
5 keypad fire alarm the output starts on triggering the fire alarm by the user (with the FIRE ALARM
function). The output operation can be limited to the alarms from specified partitions. The output can
remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is
cleared by the user. During operation, it can every second change its state (pulsate).
6 keypad panic alarm the output starts on triggering the PANIC alarm by the user. The output
operation can be limited to the alarms from specified partitions. The output can remain active for a
specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is cleared by the
user. During operation, it can every second change its state (pulsate).
7 keypad aux. alarm the output starts on triggering the alarm by the user with the ALARM AUX
function. The output operation can be limited to the alarms from specified partitions. The output can
remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is
cleared by the user. During operation, it can every second change its state (pulsate).
8 keypad tamper alarm the output starts on detecting violation of the tamper contact or a change of
the keypad address, and also after 3 wrong codes. The output operation can be limited to the alarms
from specified partitions. The output can remain active for a specified time (from 01 to 99 seconds or
from 01 to 99 minutes) or until the alarm is cleared by the user. During operation, it can every second
change its state (pulsate).
9 day/night + counting the output starts on detecting violation of disarmed DAY/NIGHT zone or
violations of COUNTING zones, which trigger no alarm. Operation of the output can be restricted to
a specified “list of outputs” or particular partitions (identically as for the 1 output type). Indication of any
other zones than those tested by this output type is irrelevant they will give no violation signal. The
output can remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until
the alarm is cleared by the user. During operation, it can every second change its state (pulsate).
10 duress alarm the output starts on using an access code with authority level 4 (DURESS) to disarm
the system or to signal an alarm. This code is used to trigger a special "disarm under duress" alarm.
Operation of the output can be restricted to alarms from particular partitions. The output can remain
active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the alarm is
cleared by the user. During operation, it can every second change its state (pulsate).
11 chime the output starts on violating the disarmed zones for which the “chime” option has been
activated. Operation of the output can be restricted to the indicated "list of zones" or to specified
partitions (identically as for the 1 output type). The output can remain active for a specified time (from
01 to 99 seconds or from 01 to 99 minutes) or until the alarm is cleared by the user. The output signals
violations irrespective of the chime lock setting in keypad (the lock is called by holding down the [8]
key).
12 switch MONO the output is activated by calling the user function 7 ([CODE][
*
][7]) or using a code
with authority level 5 ([CODE][#]). Operation of the output can be restricted to specified partitions.
The output can remain active for a time from 01 to 99 seconds or from 01 to 99 minutes.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel CA-10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel CA-10

Satel CA-10 Bedienungsanleitung - Deutsch - 2 seiten

Satel CA-10 Bedienungsanleitung - Deutsch - 4 seiten

Satel CA-10 Zusatzinformation - Deutsch - 64 seiten

Satel CA-10 Zusatzinformation - Deutsch - 24 seiten

Satel CA-10 Bedienungsanleitung - Deutsch - 26 seiten

Satel CA-10 Installationsanweisung - Deutsch - 44 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Zusatzinformation - Englisch - 60 seiten

Satel CA-10 Zusatzinformation - Englisch - 24 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 24 seiten

Satel CA-10 Kurzanleitung - Englisch - 11 seiten

Satel CA-10 Bedienungsanleitung - Holländisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info