699577
8
Zoom out
Zoom in
Vorherige Seite
1/43
Nächste Seite
6 Installer Manual SATEL
13 switch BI (ON/OFF) the output changes its state when the user function 8 is called or a code with
authority level 6 is used. Operation of the output can be restricted to specified partitions.
14 arm status the output is active when the system is armed. Operation of the output can be restricted
by indicating a „list of zones” or specific partitions. Unless zones and partitions are indicated, the
output is active when any partition (zone) is armed.
15 silent arm status the output is active when the system is in the silent armed mode. Operation of
the output can be restricted by indicating a „list of zones” or specific partitions.
16 exit delay status the output is active during the „exit delay” countdown by the control panel.
Operation of the output can be limited to indicating the „exit delay” for specified partitions.
17 entry delay status the output is active during the „entry delay” countdown. Operation of the output
can be limited to indicating the „entry delay” for specified partitions.
18 telephone usage status – the output is active when the control panel is on the telephone line.
19 ground start the output is activated by the control panel to generate the GROUND START pulse
(a 2 sec. signal occurring before the control panel "lifts the handset", required by a specific type of
telephone exchanges).
20 report acknowledge the output activated for 3 seconds by the control panel, after correct
termination of the monitoring session.
21 bypass status the output is active when some zones are bypassed in the system. Operation of the
output can be limited to showing the bypass of zones specified in the list of zones, or the bypass of
indicated partition zones.
22 ready status the output is active when all the control panel zones are free from violations. Operation
of the output can be limited to showing the READY status of zones specified in the list of zones, or the
READY status of indicated zones.
23 zone violation status the output starts when one of the zones is violated. Operation of the output
can be limited to the indicated "list of zones" or specified partitions (identically as for the 1 output type).
The output can remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or
until the armed mode is deactivated or the alarm cleared.
24 telephone line trouble the output used when telephone messaging is doubled by radio
messaging; it makes possible reporting the telephone line trouble.
25 230 V AC loss indicator
26 battery trouble indicator activated when the battery voltage in three consecutive tests drops to
about 11 V.
27 power supply the output intended for powering detectors, encoders, radio lines and other
equipment with 12 V direct voltage. When programming this type of output, pay special attention to
permissible current-carrying capacity of each of the control panel outputs.
28 fire detectors power supply the output intended for powering the fire detectors. The output
closely interacts with the 24H FIRE zones. If assigned to any of the control panel outputs, the function
activates the fire alarm verification mechanism. The mechanism operates as follows: the first violation
cuts the fire detectors power supply off for about 15 seconds. The power-down results in reset of the
violated detectors. Then, the power supply is restored, but the panel will not control the 24H FIRE
zones for 10–20 seconds because of the balancing of detectors. Next, the control panel enters the
special mode of fire detectors control, which lasts about 90 seconds. If a repeated detector violation
occurs during that time, a FIRE alarm will be triggered. Otherwise, the control panel will go over to the
normal control of 24H FIRE zones. The output reacts to the "RESET POWER SUPPLY" function (user
function 9, cutoff for time programmed as the output active time).
29 power supply with RESET function the output is designated to power detectors which require
a periodical power cut-off until the state memory is cleared. The RESET mechanism is activated from
keypad through the user function 9 (calling: [CODE][
*
][9]). The voltage is cut off for time programmed
as the output active time (minimum 5 seconds).
30 timer – the output is controlled by the control panel clock; it is activated/deactivated in the hours
indicated by a corresponding TIMER.
31 audible arm status the output signals the audible armed mode. Operation of the output can be
limited to the indicated "list of zones" or specific partitions.
32 full arm status the output is only active when all zones/partitions assigned to it are in the armed
mode.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel CA-10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel CA-10

Satel CA-10 Bedienungsanleitung - Deutsch - 2 seiten

Satel CA-10 Bedienungsanleitung - Deutsch - 4 seiten

Satel CA-10 Zusatzinformation - Deutsch - 64 seiten

Satel CA-10 Zusatzinformation - Deutsch - 24 seiten

Satel CA-10 Bedienungsanleitung - Deutsch - 26 seiten

Satel CA-10 Installationsanweisung - Deutsch - 44 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 2 seiten

Satel CA-10 Zusatzinformation - Englisch - 60 seiten

Satel CA-10 Zusatzinformation - Englisch - 24 seiten

Satel CA-10 Bedienungsanleitung - Englisch - 24 seiten

Satel CA-10 Kurzanleitung - Englisch - 11 seiten

Satel CA-10 Bedienungsanleitung - Holländisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info