26 D-307500 PowerMaster 360 Installer's Guide
4.4.6 Configuring soak test mode
This option enables you to enter device zones into Soak Test mode.
To Enable the Soak Test proceed as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
Select ADD TO SOAK
TEST Option
[1]
Select the respective
device Group
[2]
Select device zone
number
[3]
Select to enable or
disable the Soak Test
[4]
[5]
02:ZONES/DEVICES
CONTACT SENSORS
Z09:Motion Sens
ID No. 120-2468
ADD TO SOAK TEST
MOTION SENSORS
Disable test
Enable test
See
[5]
to
Step 3
Enabling Soak Test mode
[1]
Enter the Installer Mode menu, select the 02.ZONES/DEVICES option (see section 4.2) and then select the ADD
TO SOAK TEST option.
[2]
Select the respective Group of the device you require to add the Soak Test. For example, MOTION SENSORS.
[3]
Scroll to select the specific device zone number.
[4]
Select between Disable test (default) or Enable test.
[5]
If set to Enable Test you must set the duration of the Soak Test before the Soak Test will start (see section 4.5.8).
You can stop the test for the relevant zone by changing the setting to Disable test at any time during the testing
period. All Soak test zones will be reset to start a new test upon occurrence of one of the following: 1) Power up
of the system; 2) Setup of Factory Default; 3) Change in system Soak Time.
4.4.7 Defining configuration defaults for device settings
PowerMaster-360 enables you to define the default parameters used during enrollment and to change them whenever
you require so that new devices enrolled into the system will be configured automatically with these default parameters
without the need to modify the configuration of each new enrolled device. You can use a certain set of defaults for
certain group of devices and then change the defaults for another group.
IMPORTANT! Devices that were already enrolled in the PowerMaster-360 system before the defaults have been
changed will not be affected by the new default settings.
To define the default parameters of a device Group proceed as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
Select DEFINE
DEFAULTS Option
[1]
Select the respective
device Group
[2]
Select the Default
Parameter
[3]
Select the new
Default Setting
[4]
[5]
02:ZONES/DEVICES
CONTACT SENSORS
DEFINE DEFAULTS
MOTION SENSORS
Alarm LED
Event Counter
Disarm Activity
Low
High
See
[5]
to
Step 3
Changing Defaults
[1]
Enter the Installer Mode menu, select the 02.ZONES/DEVICES option (see section 4.2) and then select the
DEFINE DEFAULTS option.
[2]
Select the respective Group of the device you require to define the defaults for (for example, MOTION SENSORS).
[3]
Scroll the parameter list of the Device Group and select the Default Parameter you require to change, for example
Event Counter. The list combines the parameters of all devices in the group, for example, the parameters of all
types of Motion sensors.
[4]
In the example, the existing default setting of the Event Counter for enrolled motion sensors was
Low Sensitivity (marked with ) . To change it to High, scroll the menu until the display shows High and press
the button. The new default for the Event Counter parameter setting of Motion Sensors enrolled from
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic Powermaster-360 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info