769323
24
Zoom out
Zoom in
Vorherige Seite
1/96
Nächste Seite
24 D-307500 PowerMaster 360 Installer's Guide
No.
Zone Type
Description
wired smoke detector.
17.
Guard keybox
A Guard keybox zone is usually connected to a metal safe containing the physical keys
needed to enter the building. Following an alarm, the safe becomes available to a trusted
Guard who can open the Guard keybox, obtain the keys and enter the secured premises. The
Guard keybox zone acts just like a 24H audible zone. The Guard keybox zone also provides
automatic audible internal and external siren alarm that is immediately reported to the
Monitoring Station (and does not depend on the Abort Time).
Notes:
1. Opening/closing the Guard keybox causes the PowerMaster-360 to signal the Monitoring
Station.
2. Operates with the magnetic contact device with auxiliary input.
18
Outdoor
A zone for outdoor areas where an activated alarm does not indicate intrusion into the house.
This zone generates and alarm when the system is armed both in AWAY and HOME modes.
Events are sent to private phones and not to the monitoring station.
19
Int./Delay
This zone type behaves as an Interior zone when the system is armed HOME and as
Delayed zone when the system is armed AWAY.
20
Tamper
This is a 24 hour zone operating all of the time even when the system is disarmed. The
tamper zone reports tamper alarm events from an external wired device.
21
Line Fail
This zone type is active 24 hours, even when the system is disarmed. It is used to report
phone line fail troubles from an external wired receiver, connected to a phone line.
22
PSU Fail
This zone type is active 24 hours, even when the system is disarmed. It is used to report
power supply fail troubles from an external wire device.
23
Panic
This zone type is active 24 hours, even when the system is disarmed. It is used to report
panic events from panic devices to the monitoring station or private telephone numbers. A
panic event generates an audible siren alarm.
24
Freezer Trbl
This is a 24 hour zone that operates all of the time, even when the system is disarmed. The
freezer trouble zone reports a trouble from an external (3rd party) temperature device if it
detects a change in temperature. Freezer trouble beeps can also be produced by the siren if
enabled. This zone type is often used with refrigerators with an external output temperature
detector. If the temperature inside the refrigerator is above a defined value the refrigerator
can trigger the output connected to the freezer trouble zone type and the PowerMaster panel
will trigger a freezer trouble alert.
()
These Zone types are useful mainly when you arm and disarm the system from inside the protected premises. If
you arm and disarm the system from outside (without tripping any sensor), such as using a keyfob, it is
preferred to use the other Zone Types.
4.4.3 Deleting a device
Step 1
Step 2
Step 3
Step 4
Step 5
Select "DELETE
DEVICES" Option
[1]
Select the respective
device Group
[2]
Select exact device
you require to
delete
[3]
To delete the device:
press the key
[4]
02:ZONES DEVICES
CONTACT SENSORS
DELETE DEVICES
MOTION SENSORS
Z01:Motion Sens
ID No. 120-1254
<OFF> to delete
to
step 2
Deleting a Device
[1]
Enter the Installer Mode Menu, select the 02.ZONES/DEVICES option (see section 4.2) and then select the
DELETE DEVICES option.
[2]
Select the respective group of the device you require to delete. For example, MOTION SENSORS.
[3]
Scroll the Device Group, identify (by zone and/or ID number) the exact device you require to replace, for
example: Z01: Motion Sensor > ID No. 120-1254 and press the button.
[4]
The display prompts you <OFF> to delete. To delete the device, press the (OFF) button.
4.4.4 Modifying or reviewing a device
To Modify or Review the device parameters proceed as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic Powermaster-360 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info